After recovery from quick startup, MEAP applications do not work properly.
Some MEAP applications do not process a task at a specified time after quick startup.
In this case, the application executes the task at an unintended timing because the elapsed time during standby for quick startup
is not counted.
Problems may occur in the following two cases.
In the case of "Schedule: Execute the task every 24 hours"
A schedule is set to start the specified task at the specified time and repeat "fixed-delay execution".
If execution is delayed for some reason, the delay time is ignored.
Problem:The task is executed when the total time excluding the standby for quick startup has reached 24 hours.
=> The task may be executed at a timing other than the time the user expects it to be executed.
31/Dec
1/Jan
2/Jan
3/Jan
4/Jan
Starting
Stopped
(Quick startup standby)
5/Jan
The timing the task is expected to be executed
The timing the task was actually executed
In the case of "Schedule: Execute the task at 00:00 every day"
A schedule is set to start the specified task at the specified time and repeat "fixed-rate execution".
If execution was delayed for some reason, two or more tasks are continuously executed to "make up for the delay".
Problem: The tasks of Jan. 1, Jan. 2, and Jan. 3 are executed after quick startup.
31/Dec
1/Jan
2/Jan
3/Jan
4/Jan
Starting
Stopped
(Quick startup standby)
5/Jan
The timing the task is expected to be executed
The timing the task was actually executed
MEAP Safe Mode
Use safe mode if you need to start up the system without worrying about extra applications. It will start up only those system
software files (including SMS) that normally start up as default files while preventing MEAP applications and the like from starting
up.
When you have made changes and restart the device, the control panel will indicate "MPS" in its lower right corner. The MEAP
applications that may have been active before you shut down the equipment will not start up on their own. Make use of safe
mode when restoring the system software as when MEAP applications or services cause a fault as the result of a conflict or
wrong sequence of registration/use. You can access to SMS in this condition so that you can take necessary measures, for
example, you can stop application that may cause the trouble.
6. MEAP Application Management
105