Error Code
Display
Message
Cause
Remedy
Pop-up History
EBD0001
-
Other processes are being per-
formed.
Send job, forwarding job, FAX
RX job, IFAX RX job, Authenti-
cation Management operation
Could not start because other
processes were being per-
formed.
EBD0002
Could not create a backup of
the data.
An error occurred during back-
up processing.
Execute again.
If the error persists, refer to
"Flow of Measures to be Taken
in the Event of Trouble" and es-
calate the issue.
EBD0003
One or more necessary appli-
cations are not installed or are
not operating correctly.
Refer to the manual.
The following MEAP applica-
tions have not been installed or
started.
• Application Configuration
Management
• Access Token Provider
Perform installation from Up-
dater.
If the error occurs again, start
the corresponding application
from SMS.
EBA0001
Could not create a backup of
the data.
An error occurred during back-
up processing.
Execute again.
If the error persists, refer to
"Flow of Measures to be Taken
in the Event of Trouble" and es-
calate the issue.
EBI0001
Could not send the backup data
because the MEAPapplication
information could not be re-
trieved.
An error occurred during back-
up processing.
Execute again.
If the error persists, refer to
"Flow of Measures to be Taken
in the Event of Trouble" and es-
calate the issue.
EBI0002
Could not create a backup of
the data.
An error occurred during back-
up processing.
Execute again.
If the error persists, refer to
"Flow of Measures to be Taken
in the Event of Trouble" and es-
calate the issue.
EBS9997
-
Could not start because this de-
vice was not operational, or the
application was stopped.
The device power source was
OFF or the MEAP application
was stopped at the date and
time of Scheduled Backup.
• Check if the device is in the
following condition at the
date and time of Sched-
uled Backup.
• The device power is ON.
• The following MEAP appli-
cations have started.
• Data Backup Service
• Application Configu-
ration Management
• Access Token Pro-
vider
EBS9998
-
Processing has been canceled
because the application was
stopped.
Data Backup Service was stop-
ped or the device power was
turned OFF while backup was
performed.
Execute backup again. If back-
up cannot be performed, obtain
the debug log of Data Backup
Service and contact the support
department of the sales com-
pany.
EBS9999
An internal error occurred.
An unexpected error occurred
within the application.
Execute again.
If the error persists, refer to
"Flow of Measures to be Taken
in the Event of Trouble" and es-
calate the issue.
EBC0001
-
Could not connect to the server.
Check Proxy Settings in Set-
tings/Registration, as well as
the other network settings for
this device.
An error occurred in the proxy
or network.
Check the following settings to
make sure that the device can
connect to Cloud.
• The device is connected
the network.
• The device is connected
the proper network envi-
ronment.
• Proper values are set in
[Settings/Registration] ->
[Network] of the device.
-
Could not send the backup data
to the server.
Check Proxy Settings in Set-
tings/Registration, as well as
the other network settings for
this device.
7. Backup/Restoration
133