CHAPTER 2 STANDARDS AND ADJUSTMENTS
2-32P
7.1.2 Mounting the DIMM of the System Controller PCB and the DC Control-
ler PCB
1) Fit the DIMM into the slot at an angle, and shift it down.
F02-701-06
F02-701-07
The DIMM can break. Do not impose excess force.
REF.
After replacing the DIMM,
1. Clear the RAM (COPIER>FUNCTION>CLEAR>S-CON or DC-CON).
2. Enter all settings indicated by “S” or “D” on the service label.
3. Execute color displacement correction in user mode (only if the RAM on
the DC controller PCB has been executed).
If you are replacing the DIMM ROM with a new one, be sure to upgrade
the DIMM ROM of the reader controller PCB, DC controller PCB, and sys-
tem controller PCB to make sure that the versions will match.