CHAPTER 2 STANDARDS AND ADJUSTMENTS
2-25P
Sensor
Connector No.
Checks
I/O
Voltage
I/O address
display reading
S10
[2]>J302-18
Slide out cassette 2, and
Paper
Present 1
5V
Cassette 2
DC-CON>P002-10 move the sensor flag using
Absent 0
0V
pickup sensor
paper or the like.
S11
[2]>J318-6
Open the right cover, and
Paper
Present 0
5V
Vertical path
DC-CON>P001-4 move the sensor flag by
Absent 1
0V
sensor
hand.
S12
[2]>J319-2
Open the right cover, and
Paper
Present 1
5V
Pre-registration
DC-CON>P001-3 put paper over the sensor.
Absent 0
0V
sensor
S13
[1]>J119-5
Open the manual feed tray, Paper
Present 1
5V
Transparency
DC-CON>P009-5 and put paper over the
Absent 0
0V
sensor, front
sensor.
S14
[1]>J119-8
Open the manual feed tray, Paper
Present 1
5V
Transparency
DC-CON>P009-6 and put paper over the
Absent 0
0V
sensor, rear
sensor.
S15
[2]>J319-5
Put paper on the manual
Paper
Present 0
5V
Manual feed
DC-CON>P001-5 feed tray.
Absent 1
0V
paper sensor
S24
[2]>J313-2
Open the delivery assembly Web
Present 1
5V
Web length
DC-CON>P007-6 cover, and move the sensor
Short
0
0V
sensor
flag using paper or the like.
S25
[2]>J311-2
Open the fixing assembly,
Paper
Present 1
5V
Fixing assembly DC-CON>P007-0 and secure the sensor flag
Absent 0
0V
inlet sensor
in place; then, close the
fixing assembly.
S26
[2]>J311-5
Open the front cover.
Fixing
Up
0
0V
Fixing assembly DC-CON>P007-5 Slide out the transfer unit,
assemb- Down
1
5V
inlet arch sensor
and move the fixing
ly inlet
assembly inlet guide by
guide
hand.
S27
[1]>J311-8
Open the delivery assembly Light-
Present 1
5V
Inside delivery
DC-CON>P007-1 cover, and block the sensor. blocking Absent 0
0V
sensor
plate
S28 (face-down
[2]>J309-7
Release the face-down
Paper
Present 1
5V
delivery unit)
DC-CON>P007-2 delivery unit, and open
Absent 0
0V
Outside delivery
the face-down delivery
sensor
unit cover; then, move the
sensor flag by hand.
S29 (face-down
[2]>J309-4
Release the face-down
Paper
Present 1
5V
delivery unit)
DC-CON>P007-3 delivery unit, and open
Absent 0
0V
Delivery vertical
the face-down delivery
path sensor
unit cover; then, move
the sensor flag by hand.
S30 (duplex unit) [3]>J503-2
Release the face-down
Paper
Present 0
5V
Duplex unit
DC-CON>P008-1 delivery unit, and put paper
Absent 1
0V
inlet sensor
over the sensor.
Summary of Contents for imageRUNNER ADVANCE C2020
Page 4: ...i i INTRODUCTION ...
Page 12: ......
Page 36: ......
Page 44: ......
Page 45: ...APPENDIX ...
Page 46: ......
Page 52: ......
Page 53: ...Printer Unit COPYRIGHT 2000 CANON INC 2000 CANON C2050 2020 C2100 2100S REV 0 NOV 2000 ...
Page 54: ......
Page 101: ...CHAPTER 3 ARRANGEMENT AND FUNCTIONS OF ELECTRICAL PARTS 3 5P 2 Thermistor Lamps and Heaters ...
Page 121: ...APPENDIX ...
Page 122: ......
Page 132: ...A 10P APPENDIX ...
Page 134: ......
Page 136: ......
Page 140: ......
Page 141: ...Service Mode COPYRIGHT 2000 CANON INC 2000 CANON C2050 2020 C2100 2100S REV 0 NOV 2000 ...
Page 142: ......
Page 160: ...SERVICE MODE S 18 COPIER DISPLAY G Indicates the location 0 machine 1 feeder 2 finisher ...
Page 262: ......
Page 263: ...Error Code COPYRIGHT 2000 CANON INC 2000 CANON C2050 2020 C2100 2100S REV 0 NOV 2000 ...
Page 264: ......