Notice of proactive measure against E068-0001
[Detail]
If the pre-transfer corona wire of the pre-transfer corona ass'y is used beyond the estimated life (feeding paper 500,000 sheets,
estimated life in the environment of high temperature/high humidity (30
℃
/80%) is feeding paper 250,000 sheets), the corona wire
may be deteriorated and E068-0001 may occur. The symptom is more likely to occur in the environment of high temperature and
high humidity.
Here is the notice of the measure to prevent this symptom from occurring.
-E068-0001: Pre-transfer charging high voltage output leak error
[Remedy]
When the service technician visits the customer, check whether the feeding paper exceeds 500,000 sheets, which is the estimated
life . If it exceeds, refer to Service Manual [4.Parts Replacement and Cleaning > Image Formation System > Replacing the Pre-
transfer Charging Wire], and replace the pre-transfer corona wire with the new one (FL3-4559-000).
[ Service parts]
- FL3-4559-000 WIRE, PRE-TRANSFER CORONA