Message is wrongly displayed due to the displaced waste staple
case (Staple Finisher-X1 / Booklet Finisher-X1 / Staple Finisher-
N1 / Booklet Finisher-N1)
[Symptom]
Even though the waste staple case is not full, the following message may be displayed.
Model
Message
iR-ADV 8200 Series
Check the staple waste tray.
iR-ADV 8500 Series
[Cause]
Due to the high position [a] of the leaf spring [2] of the staple collect unit [1], the waste staple case [3] is loosely fixed, the waste
staple case is displaced, and the needle chip full sensor [4] detects falsely, which causes the above-mentioned symptom.
[Service work]
If the above-mentioned symptom occurs, add the shim (XD1-1104-635) by following the procedures below.
Adding the shim and lowering the position of the leaf spring [1] will fix the waste staple case [2] more firmly and it will become
less prone to be displaced.