E017-0002/0003 due to interference of a harness and a sensor flag
[Symptom]
Either E017-0002 or 0003 may be displayed.
- E017-0002 : ETB engagement error
- E017-0003 : ETB HP error
[Cause]
Harness [3] of the ETB disengage sensor [2] of the solenoid assembly [1] may interfere with a sensor flag [4], causing sensor
flag rotation failure. This may lead to aforementioned symptom.
[Remedy]
1) Refer to [4. Parts Replacement and Cleaning > Image Formation System > Removing the ETB Unit] of the Service Manual,
and follow the instructions to remove the ETB unit.
2) Check the harness of the ETB disengage sensor [2] of the solenoid assembly [1], and if any interference is seen [a], correct
the harness to the position where it does not touch the harness flag [b].
If any damage or torn coating is seen on the ETB disengage sensor harness, replace the solenoid assembly (FM4-0889-010)
with a new one.
85