E840-0001 due to rotation failure of a drive shaft in the upper fixing
ass'y
[Symptom]
E840-0001 may occur
- E840-0001 : Fixing Shutter Motor error
[Cause]
Due to deformation and burrs of a drive shaft in the upper fixing ass'y, the load (torque) may be increased to cause abnormal
rotation, leading to the aforementioned symptom.
[Remedy]
Rotate the drive shaft [a] in the fixing ass'y manually, in the clockwise/anti-clockwise direction until it stops. If the shaft does not
rotate smoothly, refer to the service manual, prepare and replace with the new upper fixing ass'y (FM3-7358-060).
[Service parts]
- FM3-7358-060 FIXING ASS'Y, UPPER