Error Code
E808-0007 Caused by the fixing drawer cable breakage
[Symptom]
E808-0007 may occur.
- E808-0007 : Fixing Power Supply error
[Cause]
The fixing drawer cable [1] comes in contact with the sheet metal [a], and the cable coating is broken and short-circuited to cause
the above-mentioned symptom.
[Reference] There was a case that the short-circuit caused the defective main drive driver PCB assembly and the relay PCB
assembly.
58
Summary of Contents for imageRUNNER ADVANCE 8500 series
Page 37: ...iR ADV 8585i 120V USA G SWP00501 iR ADV 8505 220V CN SWE00105 33 ...
Page 53: ...4 5 Make some prints and check that the above issue does not occur 49 ...
Page 66: ...2 Remove the grate shaped lower guide 2 screws 2 62 ...
Page 70: ...7 Reattach the metal plate 1 Screw 2 x1 8 Loosen the 2 screws 1 66 ...
Page 74: ...iR ADV 8505 220V CN To be informed as soon as identified 70 ...
Page 90: ... Service parts FM4 0889 010 solenoid assembly 86 ...