C) When loosening the yellow screws in the slider
When loosening the yellow screws in the slider, place the primary corona assembly sideways as in the photo [A] and loosen the
screws. The leaf spring of the shutter may deform when placing the unit as in the photo [B] and loosening the screws.
D) When removing and installing the shutter
When removing the shutter hook [1] one by one as shown in the photo [A] to remove the shutter, the leaf spring on back of the
shutter sheet may deform when opening the shutter hook wide while the other shutter hook is intact. In addition, when installing
the shutter, holding the shutter hook [1] with one hand as in the photo [B] trying to install the both ends at once may cause a
deformation of the leaf spring on back of the shutter sheet.
When removing the shutter from the shutter slider [1], remove it while pressing the hook claws [2] of the shutter with both hands.
Also, when installing it, insert the hooks [2] to the shutter slider [1] while holding the hook claws [2] of the shutter with both hands.
199
Summary of Contents for imagePRESS C10000VPSeries
Page 1: ...Troubleshooting Guide imagePRESS C10000VPSeries July 16 2019 Canon U S A Inc ...
Page 28: ...4 If the symptom does not improve then check other factors 23 ...
Page 42: ...3 Output about 10 test prints to verify the effect 37 ...
Page 142: ...Model Serial number PAPER DECK UNIT_ F1 A4 WES05369 137 ...
Page 164: ...4 5 Make some prints and check that the above issue does not occur 159 ...
Page 179: ...C 2 24VB system C 3 24VC system C 4 24VD system C 5 24VE system 174 ...
Page 180: ...C 6 24VF system C 7 24VH system C 8 24VI system C 9 24VJ system 175 ...
Page 181: ...176 ...
Page 261: ... Service parts CABLE MOTOR CONNECTING FM1 T808 256 ...