Specifications-Related
Announcement about checking the color sensor service label
value on installation of the device
[Symptom]
The density may not be adjusted within specification even after auto gradation adjustment has been executed during installation.
[Cause]
The color sensor detection sensitivity is adjusted on the combination of the main station [1] and the sub-station [2] at the factory.
The calculated adjustment value is put down to the service label and the label is affixed to the sub-station [2]. At the same time,
the adjustment value is entered to DCON of the main station [1], and both of them are shipped in sets [A].
Hence if a main station and a sub-station is installed in field in a combination that is different from that at the time of shipment
from the factory [B] , the adjustment value of the color sensor detection sensitivity that was entered to the main station [1] may
not be suitable for the auto gradation adjustment processing, and the aforementioned symptom may occur.
[Service work]
Perform the work following the installation procedure.
[Note] The installation procedure in the service manual has been revised with version 2.0 issued in February 2016 and the versions
onward.
1) In the step "Supplying the Starter" of the installation procedure in the service manual, put down the value of the following 12
items in the service label which is put on the sub-station. Service label is located near [a].
• CS1MID-K
• CS2MID-Y
• CS3MID-M
• CS4MID-C
• CS1OFF-K
• CS2OFF-Y
• CS3OFF-M
• CS4OFF-C
• CS1OFW-K
• CS2OFW-Y
• CS3OFW-M
• CS4OFW-C
237
Summary of Contents for imagePRESS C10000VPSeries
Page 1: ...Troubleshooting Guide imagePRESS C10000VPSeries July 16 2019 Canon U S A Inc ...
Page 28: ...4 If the symptom does not improve then check other factors 23 ...
Page 42: ...3 Output about 10 test prints to verify the effect 37 ...
Page 142: ...Model Serial number PAPER DECK UNIT_ F1 A4 WES05369 137 ...
Page 164: ...4 5 Make some prints and check that the above issue does not occur 159 ...
Page 179: ...C 2 24VB system C 3 24VC system C 4 24VD system C 5 24VE system 174 ...
Page 180: ...C 6 24VF system C 7 24VH system C 8 24VI system C 9 24VJ system 175 ...
Page 181: ...176 ...
Page 261: ... Service parts CABLE MOTOR CONNECTING FM1 T808 256 ...