E842-0051/0052 due to shift in position of the Secondary Fixing
Delivery Lower Separation Claws
[Symptom]
E842-0051 or E842-0052 may occur when turning on the main power of machine after being shipped without cushioning materials.
-E842-0051: An error in engagement operation of the Secondary Fixing Separation Claw was detected during initialization.
-E842-0052: An error in disengagement operation of the Secondary Fixing Separation Claw was detected during initialization.
[ Cause]
When shipping a machine without cushioning materials, the Secondary Fixing Delivery Lower Separation Claws may shift
diagonally due to vibration from shipping. When turning on the main power of the machine, the Secondary Fixing Delivery Lower
Separation Claws cannot perform the engage or disengage motion, resulting in the above symptom.
[ Service Work]
1) Open the Sub Station Front Right Cover[1]and the Sub Station Front Left Cover[2].
2) Unlock the lever(C-B4)[1], and pull out the Secondary Fixing Assembly [2].
3) Lift up the lever(C-B5) [1], and open the Secondary Fixing Inner Delivery Unit [2].
4) Reposition the separation claw of the inner delivery unit straight by moving the fixing claw mounting screw [a].
194
Summary of Contents for imagePRESS C10000VPSeries
Page 1: ...Troubleshooting Guide imagePRESS C10000VPSeries July 16 2019 Canon U S A Inc ...
Page 28: ...4 If the symptom does not improve then check other factors 23 ...
Page 42: ...3 Output about 10 test prints to verify the effect 37 ...
Page 142: ...Model Serial number PAPER DECK UNIT_ F1 A4 WES05369 137 ...
Page 164: ...4 5 Make some prints and check that the above issue does not occur 159 ...
Page 179: ...C 2 24VB system C 3 24VC system C 4 24VD system C 5 24VE system 174 ...
Page 180: ...C 6 24VF system C 7 24VH system C 8 24VI system C 9 24VJ system 175 ...
Page 181: ...176 ...
Page 261: ... Service parts CABLE MOTOR CONNECTING FM1 T808 256 ...