CANON iR5000i/iR6000i REV.0 JUNE 2001
CHAPTER 4 IMAGE FORMATION SYSTEM
4-11 P
2.2 Determining Primary Current
To measure the dark area potential (VD) for the first time after the power switch is turned
on, the current used during previous measurement is let to flow, and the potential sensor is
used to measure the surface potential of the drum.
The DC controller PCB compares the surface potential of the drum against the target po-
tential; if the measured potential is ±6 V or higher than the target value, the primary current
is corrected, and the potential is measured once again. The potential is measured as many as
eight times, and the primary charging current is corrected as many as eight times.
F04--202-01
WMUPR
WMUP
STBY
200˚C
Potential sensor
Primary charging
Grid bias
Vpc
Vpc
Vpc
Vpc
VD
+6V
-6V
VD
VD
Correction
control
sequence start
Potential
control
sequence start
Previous
potential
VD
VD
VD
VD
VD
Target VD
Target
VD
Fixing assembly temperature195˚C
Summary of Contents for Image Reader-A1
Page 10: ......
Page 14: ......
Page 16: ......
Page 50: ......
Page 78: ......
Page 80: ......
Page 116: ......
Page 118: ......
Page 122: ......
Page 130: ......
Page 162: ......
Page 178: ......
Page 180: ......
Page 192: ......
Page 202: ......
Page 224: ......
Page 226: ......
Page 240: ......
Page 326: ......
Page 406: ......
Page 408: ......
Page 452: ......
Page 508: ......
Page 510: ......
Page 556: ......
Page 570: ......
Page 578: ......
Page 592: ......
Page 594: ......
Page 600: ......
Page 648: ......
Page 651: ......
Page 766: ......
Page 872: ......
Page 874: ......
Page 896: ......
Page 897: ...COPYRIGHT 2001 CANON INC 2000 2000 2000 2000 CANON iR5000i iR6000i REV 0 JUNE 2001 APPENDIX ...
Page 898: ......
Page 908: ......
Page 914: ......