COPYRIGHT © 2001 CANON INC.
2000 2000 2000 2000
CANON iR5000i/iR6000i REV.0 JUNE 2001
CHAPTER 5 PICK UP/FEEDING SYSTEM
5-71 P
4) Remove the two mounting screws [4],
and detach the reversal motor [5] from
the support plate.
F05-906-04
9.6.4 Mounting the Reversal Motor
1) While the spring [1] has most tension,
tighten the two mounting screws [2]
temporarily.
F05-906-05
2) Mount the support plate [4] (2 pc.) and
the motor [5] using three mounting
screws [3]; then, attach the timing belt
[6].
F05-906-06
[4]
[4]
[5]
[1]
[1]
[2]
[2]
[3]
[3]
[6]
[4]
[5]