7) Cut off the excess of the charging wire
with nippers.
8) Pick the end of the charging wire ten-
sion spring with tweezers, and hook it
on the charging power supply electrode.
In the case of the pre-transfer charging
assembly, hook the spring on the pin at
the front.
F04-708-05
Make sure of the following:
• The charging wire must not
be bent or twisted.
• The charging wire must be
fitted in the V-groove of the
charging wire positioner.
F04-708-06
9) Attach a cushoin in front of the charg-
ing wire. (This does not apply to the
primary charging assembly.)
10) Mount the shielding plate (left, right).
For other charging assemblies,
mount the two lids.
11) Mount the wire cleaner. At this time,
pay attention to make sure that the wire
cleaner is oriented correctly.
12) Wipe the charging wire with lint-free
paper moistened with alcohol.
Correct
Correct
Wrong
Wrong
Grid side
Summary of Contents for Image Reader-A1
Page 10: ......
Page 14: ......
Page 16: ......
Page 50: ......
Page 78: ......
Page 80: ......
Page 116: ......
Page 118: ......
Page 122: ......
Page 130: ......
Page 162: ......
Page 178: ......
Page 180: ......
Page 192: ......
Page 202: ......
Page 224: ......
Page 226: ......
Page 240: ......
Page 326: ......
Page 406: ......
Page 408: ......
Page 452: ......
Page 508: ......
Page 510: ......
Page 556: ......
Page 570: ......
Page 578: ......
Page 592: ......
Page 594: ......
Page 600: ......
Page 648: ......
Page 651: ......
Page 766: ......
Page 872: ......
Page 874: ......
Page 896: ......
Page 897: ...COPYRIGHT 2001 CANON INC 2000 2000 2000 2000 CANON iR5000i iR6000i REV 0 JUNE 2001 APPENDIX ...
Page 898: ......
Page 908: ......
Page 914: ......