5) Slide off the guide [1].
- 1 claw [2]
F-3-25
6) Remove the cable from the cable guide [1].
F-3-26
7) Remove the cable guide [1].
- 1 claw [2]
F-3-27
8) Remove the rod [1] from the shaft [2].
F-3-28
9) Remove the link after aligning the link [1] with the cut-off in the shaft [2].
F-3-29
10) Remove the cable from the cable guide [1].
F-3-30
11) Remove the cable guide [1].
- 1 screw [2]
- 2 claws [3]
F-3-31
12) Remove the plate [1].
- 3 screws [2]
F-3-32
13) Remove the main drive unit [1].
- 4 screws [2]