Chapter 5
5-9
5.3.3 A4-XX_ERROR
0014-7331
/ i-SENSYS LBP5360
T-5-5
5.3.4 A5-XX_ERROR
0014-7332
/ i-SENSYS LBP5360
T-5-6
5.3.5 A7-XX_ERROR
0014-7333
/ i-SENSYS LBP5360
0001
Not enough HDD space
Occurs when the capacity of the installed HDD is smaller than an HDD space
required for a software.
-
0002
Downloading the controller firmware has been failed.
- Download the controller firmware again
- Replace controller PCB assembly
0003
HDD access error
Error caused by a device or hardware in HDD access while executing bootrom.
(Sector failure, device is busy, etc.)
Replace HDD
E604
Error in lacking of memory capacity
0000
Lack of memory capacity
- Remove and insert the expanded memory
- Replace the expanded memory to the correct one
- Replace the controller PCB
E733
Error in communication of printer system
0001
Error in communication between the DC controller PCB and the video
controller PCB (DC controller PCB factor).
- Reactivation of power
- Replace the DC controller PCB
0004
Undefined command error
0005
Communication timeout error
0006
Unknown communication error
E744
Error in invalid ID code when downloading firmware for controller
1000
Recognizing the invalid ID code when downloading firmware for controller.
Check each project ID, and download the firmware with valid
project ID.
E760
Error in software program for video controller
0000
Fault of software program for the video controller
- Download the correct firmware for the video controller
- Replace the video controller PCB
E804
Error in power supply fan
0000
Description
The fan lock detection signal is input for about 10 sec or longer continuously.
Cause
Power supply fault, DC controller PCB fault.
- Replace the power supply fan
- Replace the DC controller PCB
E805
Error in duplexing fan/CPU fan
0003
Description
The CPU fan lock detection signal is input for about 10 sec or longer
continuously.
Cause
CPU fan fault, video controller PCB fault.
- Replace the CPU fan
- Replace the video controller PCB
0005
Description
The duplexing fan lock detection signal is input for about 10 sec or longer
continuously.
Cause
Duplexing fan fault, DC controller PCB fault.
- Replace the duplexing fan
- Replace the DC controller PCB
E840
Error in pressure release mechanism
0000
Description
Although passing 2.5 sec from the start of HP control, HP (pressure condition)
cannot be controlled.
Cause
Fixing drive assembly fault, fixing pressure release cam fault.
- Replace the fixing drive assembly
- Replace the fixing pressure release cam
Number field
Description
Corrective action
A4-00 to 06
A fault exits in the software program of the video controller.
- Turn off and then on the power.
- Replace the video controller board.
Number field
Description
Corrective action
A5-00 to 07
A fault has occurred while image data is being processed by the controller. 1) Turn on the power.
2) If step 1 fails, increase the memory.
3) If step 2 fails, replace the control board.
Code
Description
Action
Summary of Contents for i-SENSYS LBP5300 Series
Page 1: ...Feb 27 2007 Service Manual i SENSYS LBP5300 Series ...
Page 2: ......
Page 6: ......
Page 13: ...Chapter 1 PRODUCT DESCRIPTION ...
Page 14: ......
Page 16: ......
Page 33: ...Chapter 2 TECHNICAL REFERENCE ...
Page 34: ......
Page 81: ...Chapter 3 DISASSEMBLY AND ASSEMBLY ...
Page 82: ......
Page 86: ......
Page 116: ...Chapter 3 3 30 11 Remove the fixing motor 1 2 screws 2 F 3 226 ...
Page 117: ...Chapter 4 MAINTENANCE AND INSPECTION ...
Page 118: ......
Page 120: ......
Page 122: ......
Page 123: ...Chapter 5 TROUBLESHOOTING ...
Page 124: ......
Page 126: ......
Page 128: ...Chapter 5 5 2 F 5 3 feed direction c a b Center of A Letter sized ...
Page 148: ......
Page 149: ...Feb 27 2007 ...
Page 150: ......