Chapter 3
3-26
3.5.2 Fixing Sleeve Unit
3.5.2.1 Preparation for Removing the Fixing Sleeve Unit
0014-8837
/ i-SENSYS LBP5360 / i-SENSYS LBP5300
1) Remove the fixing assembly.
(page 3-25)
[Removing the Fixing
Assembly]
3.5.2.2 Removing the Fixing Sleeve Unit
0013-9996
/ i-SENSYS LBP5360 / i-SENSYS LBP5300
1) Turn the gear [1] to the position [2] in the direction of the arrow.
F-3-190
F-3-191
2) Remove the screw [1].
F-3-192
3) Free the claw [1] and claw [2] in this order to detach the cover [3].
F-3-193
4) Detach the cover [1].
- 2 screws [2]
- 1 claw [3]
F-3-194
5) Detach the guide [1].
- 2 claws [2]
F-3-195
F-3-196
When detaching the guide, set the protective sheet [1] to the fixing sleeve to
prevent scratch.
F-3-197
6) Detach the cover [1].
- 1 claw [2]