Service Mode > TESTMODE > SCAN > ADFTEST
Service Mode > TESTMODE > SCAN > ADFTEST
TESTMODE
SYSTEM
■
DRAM
TESTMODE > SYSTEM > DRAM
Small Item
Description
TEST1
Data read/write check for DRAM (except system work area)
■
SPEAKER
TESTMODE > SYSTEM > SPEAKER
Small Item
Description
ON
Volume level is stepped up by 1 from minimum to maximum every time pressing
OK key. When the volume level is reached to maximum, it changes to silence and
minimum volume.
MIN
Play with minimum volume by pressing OK key.
MAX
Play with maximum volume by pressing OK key.
T-8-44
T-8-45
SCAN
■
ADJUST
●
ADF-ADJ
TESTMODE > SCAN > ADJUST > ADF-ADJ
Small Item
Description
DF-SPEED
Enter the adjustment value for the magnification ratio in vertical
scanning direction in stream feeding
Unit : 0.1 %
Setting range: -30 ~ 30
DF-OFFSET
Enter for the adjustment of DF original stop position
Unit : 0.1 mm
Setting value: -30 ~ 30
■
SENSOR
TESTMODE > SCAN > SENSOR
Small Item
Description
TRAY PAPER SENS
Display the status of Multi Pickup Sensor
ON: Paper existing OFF: No paper
REGI SENS
Display the status of Leading Edge Sensor
ON: Paper existing OFF: No paper
ESS DOOR SENS
Display the status of Delivery Tray Open/ Close Switch
ON : Close OFF : Open
■
ADFTEST
TESTMODE > SCAN > ADJUST > ADFTEST
Small Item
Description
SPEED
For testing of ADF feeding speed. Execute feeding test of ADF motor at
specified speed.
[Setting value]
STD-FAX
Fine-FAX
SFine-FAX
Copy
COUNT
Page counter for originals: Existing
START
Start feeding
T-8-46