2
2
2-43
2-43
Technology > Controls > DADF > Original Size Detection
Technology > Controls > DADF > Original Size Detection
b. Inch Type
(Unit: mm)
Original width
volume (VR)
AB/Inch
identification
sensor (SR7)
LTR-R/LGL
identification
sensor (SR8)
Post-
separation
sensor
(PCB3)
Measurement
value in feed
direction
Detected size
Width > 289
-
-
ON
-
LDR
-
-
OFF
-
LTR
289 =/> width >
272
-
-
ON
-
LDR
-
-
OFF
-
LTR
272 =/> width >
247
-
-
ON
-
LDR
-
-
OFF
-
LTR
247 =/> width >
200
-
-
ON
-
LGL
-
-
OFF
length =/> 209
LTR-R
-
-
OFF
length < 209
STMT
200 =/> width >
172
-
-
ON
-
LGL
-
-
OFF
length =/> 209
LTR-R
-
-
OFF
length < 209
STMT
172=/> width
-
-
-
-
STMT-R
T-2-21
c. AB/ Inch mixed
(Unit: mm)
Original width
volume (VR)
AB/Inch
identification
sensor (SR7)
LTR-R/LGL
identification
sensor (SR8)
Post-
separation
sensor
(PCB3)
Measurement
value in feed
direction
Detected size
width > 289
-
-
ON
-
A3
-
-
OFF
-
A4
289 =/> width >
272
-
-
ON
-
LDR
-
-
OFF
-
LTR
272 =/> width >
247
-
-
ON
-
B4
-
-
OFF
-
B5
247 =/> width >
200
OFF
-
-
length =/> 222
A4-R
OFF
-
-
length < 222
A5
ON
-
ON
-
LGL
ON
-
OFF
length =/> 209
LTR-R
ON
-
OFF
length < 209
STMT
200 =/> width >
172
-
-
-
-
B5-R
172 =/> width >
138.5
OFF
-
-
-
STMT-R
ON
-
-
-
A5-R
138.5 =/> width
-
-
-
length =/> 200
STMT-R
-
-
-
length < 200
B6-R
T-2-22