Parts Replacing and Cleaning > Consumable parts for periodical replacement and locations for cleaning (DADF) > Cleaning the Registration Sensor/Lead Sensor/Registration Roller > Procedure
Parts Replacing and Cleaning > Consumable parts for periodical replacement and locations for cleaning (DADF) > Cleaning the Registration Sensor/Lead Sensor/Registration Roller > Procedure
Cleaning the Registration Sensor
4) Clean the prism [1] of the Registration Sensor by blowing air a couple of times with a
blower [2]. (When wiping, be sure to use wet and tightly-wrung lint-free paper.)
CAUTION:
When cleaning the prism of the Registration Sensor, do not disassembly the Prism Unit
[2] from the Registration Guide [1].
[1]
[2]
F-4-146
[1]
[2]
F-4-147
Cleaning the Lead Sensor
5) Clean the Lead Sensor [1] by blowing air a couple of times through the clearance [A] of
the guide with a blower [2]. When wiping it, be sure to use wet and tightly-wrung lint-free
paper.)
[1]
[2]
[A]
Cleaning the Registration Roller
6) Wipe the Registration Roller [2] with wet and tightly-wrung lint-free paper [3] by rotating the
shaft [1] of the Registration Roller until it is clean.
[1]
[2]
[3]
F-4-148
F-4-149