![background image](http://html.mh-extra.com/html/canon/dr-x10c-imageformula-document-scanner/dr-x10c-imageformula-document-scanner_user-manual_62896081.webp)
81
Display Language Setting
Selects Japanese or English for the language to display on the control
panel.
ON: Japanese display panel
OFF: English display panel
Display Contrast Adjustment
Use to adjust display panel contrast.
SCSI Speed Setting
Selects the scanner’s SCSI transfer speed.
If the scanner does not operate normally with the default [20] (20
MBytes/s) speed, change this setting to reduce the speed to [10] (10
MBytes/s) or [5] (MBytes/s).
USB Short Packet Setting
If the scanner does not operate normally when using the USB
interface, change this setting to [OFF].
Dust Detect Mode Setting
If dust is detected on the scanner glass when scanning starts, the
sensor position is moved forward or backward to avoid vertical streaks
caused by the dust on the scanned image.
ON2: Displays an error message and stops scanning. (scanning
disabled)
ON: Normal display alternates with error message. (scanning
enabled)
OFF: Dust detection is disabled.
IMPORTANT
When the dust detection error message is displayed (either
continuously or alternating with the normal display), clean the
scanning glass.