OSD Menu
54
Sub Menu
Setting Options (Bold: factory default)
Scale
Automatic
IRE
SMPTE ST 2084 (PQ)
Hybrid Log-Gamma
Canon Log
Canon Log 2
Canon Log 3
S-Log2
S-Log3
ARRI (Rec2100-PQ-
1K-100)
ARRI (Rec2100-HLG-
1K-200)
Sets the scale of the wave form monitor.
[Automatic]: Sets in accordance with the [Gamma/EOTF] and [Color
Range] settings.
• When [SMPTE ST 2084 (PQ)], [Canon Log], [Canon Log 2], or [Canon Log 3] is
set (including [Automatic]):
When [Gamma/EOTF] [SMPTE ST 2084 (PQ)], the item is displayed in
accordance with the [Color Range] settings ([SDI Full (4-1019)] is set to [Full]).
Reference Line
4 to
1023
A guide is displayed at the specified position. [Reference Line] is not
displayed when [1023] is selected.
Reference Level
Automatic
Manual
Sets the range of the reference level. Tints the outside of the range of the
reference level.
In the case of [Gamma/EOTF] corresponding to the HDR range, parts that
exceed the HDR range are tinted. When [YRGB] is selected, no tinting is
performed.
When [Color Range] [Limited], outside the limited range is tinted.
[Automatic]: Sets in accordance with the [Gamma/EOTF] and [Color
Range] settings.
Reference Level
High
468 to 1023
Sets the reference display level (high). [Reference Level High] is not
displayed when [1023] is selected.
Reference Level
Low
0 to 468
Sets the reference display level (low). [Reference Level Low] is not
displayed when [0] is selected.
Color
Sets the signals to be displayed and the color of signals exceeding the reference level. When [YRGB]
is selected, the color is fixed.
Y
White
Red
Green
Blue
Yellow
Cyan
Magenta
[Y], [Cb], [Cr], [R], [G], [B]: Selects the color of the selected signal.
Default value of each signal is shown below.
Y (White), Cb (White), Cr (White), R (Red), G (Green), B (Blue)
[Reference Level High], [Reference Level Low]: Selects the color of the
signal of the selected reference level.
Default value of each reference level is shown below.
Reference Level High (Magenta), Reference Level Low (Cyan)
Cb
Cr
R
G
B
Reference Level
High
Reference Level
Low
Position
Bottom Left
Bottom Right
Selects the display position.
• When [Multi View (Dual)] or [Multi Information View] is selected, this setting is
invalid.
Size
Sets the size of the display.
• When [Multi Information View] is selected, this setting is invalid.
Large,
Middle
, Small
Large, Middle,
Small