Nomenclature
11
Back face of the main unit
A
s
A
d
A
f
A
g
A
j
A
k
A
a
A
h
A
a
HDMI input terminal (
A
s
SDI input terminal (
A
d
SDI output terminal
For passing through output corresponding to
A
s
.
A
f
REMOTE terminal (
For connecting remote control devices.
A
g
LAN (10/100 BASE) terminal (
For connecting a Display Controller CL-01 (provided with the DP-V3010) and external control device.
A
h
AC power input terminal (
A
j
Cord clamp mounting hole (
A
k
DC power input terminal (
CAUTION
•
When connecting an external sensor for calibration to the USB port, the USB cable length must not exceed 3 m (9.8 ft.).
Otherwise, communication error may occur and correct calibration may not be possible.
•
For safety, do not connect any connector that may have excessive voltage to the terminal of the video display when connecting
peripheral devices.
•
Pass through SD-SDI signals are not output correctly.
Note
•
About USB Memory
-
Both FAT16 and FAT32 USB memory devices are supported.
-
Correct operation cannot be guaranteed for all USB memory devices.
-
It may take 10 seconds or more for the USB memory to be recognized. If the function to save data on a USB memory is
executed during recognition, the message [Detecting USB memory] is displayed.
•
When using the CL-01 Display Controller (supplied with the DP-V3010) with this device, first update the controller firmware to
Version 4.19.0 or later.