OSD Menu
71
Sub Menu
Setting Options (Bold: factory default)
Display Color Gamut/
Gamma
ITU-R BT.709
ITU-R BT.2020
ITU-R BT.2020 PQ 1K
ITU-R BT.2020 PQ 2K
When [Automatic Adjustment (ARRI)] [On]
Sets the color gamut and gamma shown in the display.
Anamorphic
On
, Off
When a Canon camera is connected, displays in accordance with the
settings when anamorphic lens display settings are included in the camera
metadata.
Area Marker
12
ARRI Frame line 1A
ARRI Frame line 1B
Off
When an ARRI cinema camera is connected to this device, the [H Position],
[V Position], [Width], and [Height] for the [Area Marker] change depending
on the metadata.
Fan
13
On
, Off
Allows you to link stopping the fan to the camera's recording operation
(For Cinema EOS System cameras, Canon professional-use video
cameras, or ARRI cinema cameras that are compatible with this video
display). Set [System Settings] [Fan Control] to [On] to enable the fan
to be stopped and then set [Fan] to [On] to stop the fan whenever the
camera starts recording. At room temperature (25 °C), the fan remains
off for approximately one minute (Max of about 6 minutes when using DC
power). The fan operates at a faster speed than usual before and after the
fan is stopped to lower the internal temperature.
Camera Information
Automatic
On
Off
Sets conditions to display camera information.
[Automatic]: Camera information is displayed for 4 seconds when the
information has changed.
[On]: Camera information is always displayed.
[Off]: Camera information is not displayed.
1
• [Peaking] cannot be displayed during the execution of [Playback File] under [Screen Capture].
• [Enable] changes to [Off] when the power is turned on again.
2
• [False Color] cannot be displayed during the execution of [Playback File] under [Screen Capture].
• [Enable] changes to [Off] when the power is turned on again.
• When [IRE] in [Type] is selected, [HDR Range] settings become invalid.
3
[Time Code] cannot be displayed in the following cases:
-
When [Frame Hold] is [On]
-
During the execution of [Playback File] under [Screen Capture]
-
When the location selected for [Time Code] and [Audio Level Meter] to be displayed is the same
-
When [Test Pattern] is displayed
4
This setting becomes invalid when HDMI signal is input and is fixed to [VITC].
5
This setting becomes invalid in the [Multi View (Dual)] display.
6
• [Wave Form Monitor] cannot be displayed in the following cases:
-
When an enlarged image is displayed
-
When [Frame Hold] (during interlace signal or PsF signal) is [On]
-
When [Peaking] is set to [On]
-
During execution of [Playback File] under [Screen Capture]
-
While [Test Pattern] is displayed
• Only the signal set by [Marker/TC/WFM/VEC Input] is displayed in the [Multi View (Quad)] or [Multi View (Dual)] display.
• When [Wave Form Monitor] is set to [On], [Vector Scope] turns [Off].
• When [Scale]
[Automatic] is selected: When a different [Picture Mode] is set for each side of the screen, the [Gamma] and [Color Range]
scales for the left side will be displayed. When displayed as [Multi View (Quad)] or [Multi View (Dual)]: The scales for [Gamma] and [Color Range]
for the terminal set in [Marker/TC/WFM/VEC Input] in [Channel Settings] will be displayed.