4
4
4-40
4-40
Disassembly/Assembly > Document Exposure, Feed System > Removing the ADF Separation Roller > Procedure
Disassembly/Assembly > Document Exposure, Feed System > Removing the ADF Separation Roller > Procedure
2) Remove the 2 Resin E-rings [1].
[1]
3) Displace the Roller Shaft [1] and Remove the Parallel Pin [2] and the Bushing [3].
[1]
[2]
[3]
CAUTION :
Since the Parallel Pin is very tiny, be Careful not to Lose it.
F-4-74
F-4-74
F-4-75
F-4-75
4) Turn the Shaft [1] In the Direction of the Arrow, Fit the Protrusion [2] With the Hole of the
Roller Holder and Pull It Out.
[1]
[2]
[2]
5) Remove the ADF Separation Roller [1].
[1]
F-4-76
F-4-76
F-4-77