![Canon D1100 Series Service Manual Download Page 191](http://html.mh-extra.com/html/canon/d1100-series/d1100-series_service-manual_57063191.webp)
8
8
8-4
8-4
Service Mode > Default Settings > Service Mode Menus
Service Mode > Default Settings > Service Mode Menus
#MENU
No.
Initial setting
Range of setting
Function
01: - 04:
not used
05:
0
ON/OFF
NL equalizer setting
06:
0
0: DIAL
line monitor setting
1: SERVICEMAN [1]
2: SERVICEMAN [2]
3: OFF
07:
10
0-15
transmission level setting
08:
0
0: 3429
V.34 baud rate
1: 3200
2: 3000
3: 2800
4: 2743
5: 2400
09:
0
0: 33.6kbs
V.34 transmission speed
1: 31.2kbs
2: 28.8kbs
3: 26.4kbs
4: 24.0kbs
5: 21.6kbs
6: 19.2kbs
7: 16.8kbs
8: 14.4kbs
9: 12.0kbs
10: 9.6kbs
11: 7.2kbs
12: 4.8kbs
13: 2.4kbs
10:
1
0: 50Hz
pseudo CI signal frequency setting
1: 25Hz
2: 17Hz
3: 20Hz
11: - 20:
not used
T-8-2
T-8-2
#NUMERIC
No.
Initial setting
Range of
setting
Function
001:
not used
002:
10 (10%)
(1-99)
RTN signal transmission condition (1) setting
003:
15 (15lines)
(2-99)
RTN signal transmission condition (2) setting
004:
12 (12times)
(1-99)
RTN signal transmission condition (3) setting
005:
4 (4sec)
(1-60)
NCC pause time (pre-ID code) setting
006:
4 (4sec)
(1-60)
NCC pause time (post-ID code) setting
007: - 009:
not used
010:
5500 (55sec)
(0-9999)
line connection identification time length
011:
3500 (35sec)
(0-9999)
T.30 T1 timer (for reception)
012:
not used
013:
1300 (13sec)
(500-3000)
T30 EOL timer
014:
not used
015:
120 (1200ms)
(0-999)
hooking detection time setting
016:
4 (4sec)
(0-9)
fax/tel switch-over function: between line acquisition
and pseudo RBTtransmission
017:
100 (1000ms)
(0-999)
pseudo RBT signal pattern: ON time setting
018:
0 (0ms)
(0-999)
pseudo RBT signal pattern: OFF time (short) setting
019:
200 (2000ms)
(0-999)
pseudo RBT signal pattern: OFF time (long) setting
020:
100 (1000ms)
(0-999)
pseudo CI signal pattern: ON time setting
021:
0 (0ms)
(0-999)
pseudo CI signal pattern: OFF time (short) setting
022:
200 (2000ms)
(0-999)
pseudo CI signal pattern: OFF time (long) setting
023:
4
(0-7)
fax/tel switch-over pseudo RBT transmission level
024:
20 (-20dBm)
(0-20)
fax/tel switch-over pseudo RBT transmission level
025:
60 (60sec)
(0-999)
Answering machine connection function signal
detection time
026:
not used
027:
0
(0-20)
V21 low-speed flag preamble detection time length
028: - 055:
not used
056:
101
(0-999)
count type select 1
057:
201
(0-999)
count type select 2
058:
0
(0-999)
count type select 3
059:
0
(0-999)
count type select 4
060:
0
(0-999)
count type select 5
061:
0
(0-999)
count type select 6
062: - 080:
not used
T-8-3