Chapter 16
16-12
F-16-34
b. Applying Grease to Belt Displacement Control
Motor Unit
The application parts and the amount of grease are as
follows.
-To the edge [A] of the gear [1], apply about a
soybean size of grease.
-To the center [B] of the gear [2] (inner side of the
plate [3]), apply about a soybean size of grease.
-To the edge [C] of the gear [2], apply about a
soybean size of grease.
-To the each side of the edge [D] [E] of the gear
[4], apply about a soybean size of grease.
F-16-35
2. Executing Service Mode after Fixing Unit
Replacement
When replacing the fixing unit, be sure to execute the
following operation with the service mode.
-Clear the fixing delivery counter.
COPIER > COUNTER > DRBL-1 > FX-BLT-U
-Execute the fixing belt and pressure belt HP search
operation.
COPIER > FUNCTION > FIXING > FX-UHP-S
COPIER > FUNCTION > FIXING > FX-LHP-S
Points to Note When Replacing Fixing Unit
By executing the service mode, the alarm code is
closed and the total rotation time is cleared. Thus,
this mode must be executed when replacing the
fixing unit.
If the mode is not executed, the following symptoms
will occur.
-The alarm code is not closed.
06-0002: Fixing unit life alarm (Caused by the belt
displacement)
06-0004: Fixing unit life alarm (Caused by the
torque up)
-Although the total rotation time of the replaced
fixing assemble does not reach to the message
threshold, the machine wrongly recognize that it
reaches to the threshold and displays the message.
Be sure not to execute the mode except at the
installation and the fixing unit replacement. If not, an
error message may not be displayed when the fixing
unit reaches to its life.
[A]
[1]
[B]
[A]
[D]
[E]
[3]
[B]
[C]
[2]
[4]
[1]
Summary of Contents for Color imageRUNNER C4580
Page 22: ...Chapter 1 INTRODUCTION ...
Page 64: ...Chapter 2 INSTALLATION ...
Page 110: ...Chapter 3 BASIC OPERATION ...
Page 119: ...Chapter 4 BASIC OPERATIONS AS A PRINTER ...
Page 129: ...Chapter 5 MAIN CONTROLLER ...
Page 138: ...Chapter 5 5 8 F 5 8 CPU HDD ROM access to the program at time of execution ...
Page 165: ...Chapter 6 ORIGINAL EXPOSURE SYSTEM ...
Page 209: ...Chapter 7 IMAGE PROCESSING SYSTEM ...
Page 212: ...Chapter LASER EXPOSURE 8 ...
Page 239: ...Chapter 9 IMAGE FORMATION ...
Page 324: ...Chapter 10 PICKUP FEEDING SYSTEM ...
Page 435: ...Chapter 11 FIXING SYSTEM ...
Page 460: ...Chapter 11 11 23 F 11 13 SEN3 SEN2 SEN1 SEN2 SEN3 SEN1 SEN2 SEN3 SEN1 ...
Page 491: ...Chapter 12 EXTERNALS CONTROLS ...
Page 498: ...Chapter 12 12 5 F 12 2 FM1 FM7 FM9 FM2 FM13 FM14 FM12 FM11 FM10 FM5 FM3 FM4 FM8 FM6 ...
Page 512: ...Chapter 12 12 19 2 Remove the check mark from SNMP Status Enabled F 12 10 ...
Page 553: ...Chapter 13 MEAP ...
Page 557: ...Chapter 14 RDS ...
Page 569: ...Chapter 15 MAINTENANCE INSPECTION ...
Page 578: ...Chapter 16 STANDARDS ADJUSTMENTS ...
Page 597: ...Chapter 17 CORRECTING FAULTY IMAGES ...
Page 612: ...Chapter 17 17 14 F 17 7 PLG1 ELCB1 SP1 H4 H3 H2 H1 H1 H2 LA1 ...
Page 617: ...Chapter 18 SELF DIAGNOSIS ...
Page 644: ...Chapter 19 SERVICE MODE ...
Page 778: ...Chapter 20 UPGRADING ...
Page 823: ...Chapter 21 SERVICE TOOLS ...
Page 828: ...APPENDIX ...
Page 851: ......