CHAPTER 4 SERVICE MODE
4-80
Level 3
D-SGNL-Y
D-SGNL-M
D-SGNL-C
D-SGNL-K
D-SGNL-4
(Note 1)
P-REF-Y
P-REF-M
P-REF-C
P-REF-K
(Note 1)
P-SGNL-Y
P-SGNL-M
P-SGNL-C
P-SGNL-K
(Note 1)
SIGG-K
(Note 1)
SIGG-P-M
SIGG-P-C
SIGG-P-Y
SIGG-P-K
(Note 1)
RGAN-P-M
RGAN-P-C
RGAN-P-Y
RGAN-P-K
(Note 1)
Remarks
0 to 1023
0 to 1023
0 to 1023
0 to 255
0 to 255
0 to 255
Description
Use it to adjust the signal value (during
initialization) for the toner concentration sensor of
each color in relation to light reflected by the
photosensitive drum.
Use it to adjust the signal value (during
initialization) for the toner concentration sensor of
all colors in relation to light reflected by the
photosensitive drum.
Use it to adjust the toner concentration reference
signal value for each color on the photosensitive
drum during INIT for ATR control.
Use it to adjust the toner concentration reference
signal value for each color on the photosensitive
drum during INIT for ATR control.
Use it to adjust the gain for the Bk toner
concentration reference signal during ATR control.
correction of the patch gain for ATR control when
INIT-x (mono INIT) is executed
correction of the patch gain for toner density control
when INIT-x (mono INIT) is executed
Note 1: Execute this mode upon replacement of a CPU PCB or initialization of the RAM. The settings
will be returned to standard settings, requiring you to enter the appropriate settings. Be sure to
record any new settings on the service label.