A–40
Signals transmit-
ted by receiver
CED*
Called Station Identification
T: 2100 Hz
CFR
Confirmation to Receive
B: FCF1=X010 0001
CIG*
Calling Subscriber Identifica-
tion
B: FCF1=1000 0010
CSI*
Called Subscriber Identification
B: FCF1=0000 0010
DIS
Digital Identification Signal
B: FCF1=0000 0001
DTC
Digital Transmit Command
B: FCF1=1000 0001
FTT
Failure to Train
B: FCF1=X010 0010
MCF
Message Confirmation
B: FCF1=X011 0001
NSC*
Non-Standard Facilities Com-
mand
B: FCF1=1000 0100
NSF*
Non-Standard Facilities
B: FCF1=0000 0100
PIN
Procedure Interrupt Negative
B: FCF1=X011 0100
PIP
Procedure Interrupt Positive
B: FCF1=X011 0101
RTN
Retrain Negative
B: FCF1=X011 0010
RTP
Retrain Positive
B: FCF1=X011 0011
SUB*
Subaddress:
B: FCF1=X100 0011
PWD*
Password:
B: FCF1=X100 0101
Common signals
CRP*
Command Repeat
B: FCF1=X101 1000
DCN
Disconnect
B: FCF1=X101 1111
Image signals
EOL
End Of Line
B: 0000 0000 0001
(=001H)
RTC
Return To Control:
6 continuous EOLs
RCP
Return To Control for Partial
page:
For details of HDLC
Configuration,
see page 5-108
6.8.2 Structure of
binary coded infor-
mation.
Table A-4 Signal Table
Abbreviation
(
*
indicates
option.)
Function
Format
(B: binary signal,
T: tonal signal)
On facsimile that
first receives DIS
X=0
On opposite
facsimile
X=1