5–19
1
2
3
4
5
6
ït
çi
G3 FACSIMILE COMMUNICATIONS
“parameter K”. This is standardized as shown in the table below. By this
measure, if, for example, a transmission error prevents data from being
decoded correctly, decoding can be performed correctly from after the next
MH data. The line that was coded by the MH scheme to be referenced to at
this time is called the “reference line.”
Fig. 5-16 Transmission Error and Parameter K
Table 5-4 Parameter K
Vertical Scanning Line Density
Parameter K
Standard (3.85 lines/mm)
2
Fine (7.7 lines/mm)
4
Super-fine (15.4 lines/mm)
4
Ultra-fine (15.4 lines/mm)
4
In case of parameter K = 4
Without parameter
4 lines
Transmission error
Subsequent lines cannot
be correctly decoded.
4 lines
Transmission error
These two scanlines cannot
be correctly decoded.
Error can be recovered
at this line.
MH coding (reference line)
MR coding