FACSIMILE SYSTEM
OFF within the telephone, DC current does not flow and the DC loop is not
formed.
Fig. 6-5 Formation of DC Loop (in standby state)
DC current flows as the HS turns ON when the telephone is made off-
hook, and a DC loop is formed between the
exchange
and the telephone.
Fig. 6-6 Formation of DC Loop on Telephone Side
When the facsimile side is set to receive automatically, the CML
relay
turns ON when the calling identification (CI) is detected, and the DC loop
is formed between the DC seize (RET) circuit and the exchange.
B
T1
T2
L1
L2
HS
On-hook
Off-hook
detection circuit
H relay
Exchange
CML relay
DC seiz
circuit
To 2-wire/4-wire
conversion circuit
NCU board
Off-hook
ON
Off-hook
detection circuit
H relay
Exchange
CML relay
DC seize
circuit
To 2-wire/4-wire
conversion circuit
NCU board