background image

Supplied By www.heating spares.co  Tel. 0161 620 6677

9. Guarantee

10. Safety

Your water heater is guaranteed for a period of one year.

The terms of the guarantee are explained in the guarantee certificate.
IMPORTANT : Make sure that the detachable coupon on the certificate has been returned to CHAFFOTEAUX & MAURY.
In order to benefit from the guarantee, your water heater must have been installed, adjusted and commissioned by a qualified

professional. This gives you the assurance that your installer has complied with the installation instructions and that the regula-

tions and safety conditions have been satisfied.

This water heater incorporates safety devices in compliance with the Gas Safety (Installation & Use) Regulations 1998.
-  an  atmosphere  sensing  device  which  shuts  down  the  water  heater  if  the  premises  where  it  is  installed  are  inadequately 

ventilated

- a preventive service safety device which shuts down the water heater in the event of abnormal fouling of the heating body.
The incorporation of these devices means that the appliance can be installed without being connected to a flue.
After shutdown the water heater is in the “safety” position. After approximately five minutes, it can be turned on again manually,

following the normal lighting procedure. If the appliance shuts down repeatedly, you must contact a qualified professional.
Warning :
- these safety devices must not be rendered inoperative

- only CHAFFOTEAUX & MAURY original parts must be used for replacement.

Incidents

You do not have any hot water

The water heater does not come on.

The pilot does not light.

The water heater turns off while water is

being drawn.

Causes

Water inlet valve closed.

No gas, pilot not lit

No water.

Gas valve closed
Air in the gas circuit.

Inadequate  ventilation  or  extraction  of

fumes.

Solutions

Open the valve

Light the pilot

Make the necessary checks

(gas inlet, water on).

Open the valve
May occur after a long shutdown

Repeat  the  lighting  procedure  (refer  to

section "6").
- air the premises thoroughly
-  make  sure  that  the  top  and  bottom

ventilation openings are not obstruc-

ted.

- put the appliance back into service by

lighting the pilot.

If these solutions are not effective, contact a qualified professional.

11. Operating defects

f.

:1304123- 

12/2000

Chaffoteaux & Maury

Trench Lock

Trench

Telford

TF1 4SZ

Tel 01052 222727

Fax 01952 243493

c

Summary of Contents for CELT STAR C

Page 1: ...s one piece case the water heater comprises One piece chassis made of protected steel sheet Deflector Heat exchanger made of protected copper Combustion chamber Multi gas burner made of stainless stee...

Page 2: ...bar 3 lb in2 Minimum water pressure to operate the low pressure valve 0 1 bar 1 5 lb in2 Maximum normal pressure water pressure with governor 10 bar 145 lb in2 Maximum low pressure water pressure with...

Page 3: ...rised contractor Installation pipes should be fitted in accordance with BS 6891 Pipework from the meter must be of adequate size Pipes of a smaller size than the gas connection should be not used The...

Page 4: ...appliance is delivered complete ready to install The accessories pouch contains the following items Natural gas connection fig 5 one valve 3 4 F 1 2 M with 1 2 gasket one brazed angle socket 14 x 0 75...

Page 5: ...refer to the Technical characteristics In the case of a higher supply pressure the maximum gas power can be adjusted by proceeding as follows detach the stop from the fascia fig 7a place it on the ga...

Page 6: ...the gas control knob 6 Fig 10 6 Controls and use Fig 11 Control panel fig 11 Gas control knob symbols Off Reduced power Pilot ignition Intermediate piezo triggering powers Pilot position Maximum power...

Page 7: ...fitted with a system enabling the user to limit its maximum power To do this turn the knob until it is between the and This appliance operates in such a way that it can be used over a wide range of f...

Page 8: ...thout being connected to a flue After shutdown the water heater is in the safety position After approximately five minutes it can be turned on again manually following the normal lighting procedure If...

Reviews: