Supplied By www.heating spares.co Tel. 0161 620 6677
9. Guarantee
10. Safety
Your water heater is guaranteed for a period of one year.
The terms of the guarantee are explained in the guarantee certificate.
IMPORTANT : Make sure that the detachable coupon on the certificate has been returned to CHAFFOTEAUX & MAURY.
In order to benefit from the guarantee, your water heater must have been installed, adjusted and commissioned by a qualified
professional. This gives you the assurance that your installer has complied with the installation instructions and that the regula-
tions and safety conditions have been satisfied.
This water heater incorporates safety devices in compliance with the Gas Safety (Installation & Use) Regulations 1998.
- an atmosphere sensing device which shuts down the water heater if the premises where it is installed are inadequately
ventilated
- a preventive service safety device which shuts down the water heater in the event of abnormal fouling of the heating body.
The incorporation of these devices means that the appliance can be installed without being connected to a flue.
After shutdown the water heater is in the “safety” position. After approximately five minutes, it can be turned on again manually,
following the normal lighting procedure. If the appliance shuts down repeatedly, you must contact a qualified professional.
Warning :
- these safety devices must not be rendered inoperative
- only CHAFFOTEAUX & MAURY original parts must be used for replacement.
Incidents
You do not have any hot water
The water heater does not come on.
The pilot does not light.
The water heater turns off while water is
being drawn.
Causes
Water inlet valve closed.
No gas, pilot not lit
No water.
Gas valve closed
Air in the gas circuit.
Inadequate ventilation or extraction of
fumes.
Solutions
Open the valve
Light the pilot
Make the necessary checks
(gas inlet, water on).
Open the valve
May occur after a long shutdown
Repeat the lighting procedure (refer to
section "6").
- air the premises thoroughly
- make sure that the top and bottom
ventilation openings are not obstruc-
ted.
- put the appliance back into service by
lighting the pilot.
If these solutions are not effective, contact a qualified professional.
11. Operating defects
Ré
f.
:1304123-
12/2000
Chaffoteaux & Maury
Trench Lock
Trench
Telford
TF1 4SZ
Tel 01052 222727
Fax 01952 243493
c