background image

Supplied By www.heating spares.co  Tel. 0161 620 6677

1. Technical characteristics and dimensions

Cold water

Gas

220

246

Fig. 3

2

TECHNICAL CHARACTERISTICS

Rated heat input  .................................................................................................................................... =10.0 kW (34120 Btu/h)
Rated power output ................................................................................................................................. =8.5 kW (29002 Btu/h)
Flow rate of water heated from 15 to 40 °C  ........................................................................................... =

5 I/min

Flow rate of water heated from 15 to 65 °C  ........................................................................................... =

2.5 I/min

Minimum water pressure to operate the “normal pressure” valve: ......................................................... = 0.2 bar (3 lb/in

2

)

Minimum water pressure to operate the “low pressure” valve: ............................................................... = 0.1 bar (1.5 lb/in

2

)

Maximum “normal pressure” water pressure (with governor) :................................................................ = 10 bar (145 lb/in

2

)

Maximum “low pressure” water pressure (without governor) : ................................................................ =2.5 bar (36,25 lb/in

2

)

Fresh air flow rate :.................................................................................................................................. =

21.5 m

3

/h

Gas flow rates (15°C - 1013 mbar)                                Inlet Pressure                        

Gas rate

G 20 (Natural gas)..............................................................20 mbar (8in wg).......................................... =

1.06 m

3

/h

Injector identification

...............................................................................................................................

Burner

Pilot

G 20 gas (with disc marked DIA 2.70)  ...................................................................................................... INJ 123

26-40

• 1 bar = 1,02 kg/cm

2

(the pressure must be measured at the appliance inlet, while the appliance is working).

409

102

101

Hot water

20

60

20

103

Hot water

Summary of Contents for CELT STAR C

Page 1: ...s one piece case the water heater comprises One piece chassis made of protected steel sheet Deflector Heat exchanger made of protected copper Combustion chamber Multi gas burner made of stainless stee...

Page 2: ...bar 3 lb in2 Minimum water pressure to operate the low pressure valve 0 1 bar 1 5 lb in2 Maximum normal pressure water pressure with governor 10 bar 145 lb in2 Maximum low pressure water pressure with...

Page 3: ...rised contractor Installation pipes should be fitted in accordance with BS 6891 Pipework from the meter must be of adequate size Pipes of a smaller size than the gas connection should be not used The...

Page 4: ...appliance is delivered complete ready to install The accessories pouch contains the following items Natural gas connection fig 5 one valve 3 4 F 1 2 M with 1 2 gasket one brazed angle socket 14 x 0 75...

Page 5: ...refer to the Technical characteristics In the case of a higher supply pressure the maximum gas power can be adjusted by proceeding as follows detach the stop from the fascia fig 7a place it on the ga...

Page 6: ...the gas control knob 6 Fig 10 6 Controls and use Fig 11 Control panel fig 11 Gas control knob symbols Off Reduced power Pilot ignition Intermediate piezo triggering powers Pilot position Maximum power...

Page 7: ...fitted with a system enabling the user to limit its maximum power To do this turn the knob until it is between the and This appliance operates in such a way that it can be used over a wide range of f...

Page 8: ...thout being connected to a flue After shutdown the water heater is in the safety position After approximately five minutes it can be turned on again manually following the normal lighting procedure If...