13
ENTRY CIRCUIT
Starts the entry timer when activated providing the panel is set.
FIRE
(for use with smoke detectors)
A zone that when activated emits an ascending sound from any internal
speakers. If the panel is set, external sirens and strobes also sound, but in
an unset state the external sounders pulse every two seconds.
TAMPER
A loop that should run through every device on your system. If broken, it
triggers the internal speakers. If the panel is set, external sounders and
strobes also trigger. The tamper LED appears on the keypad as
TPR.
CHIME
Chime is similar to a doorbell. This can be used to alert a user to a certain
zone being triggered during the day.
DOOR SENSE SETTING
Allows you to have a variable FULL SET EXIT TIME. You can program the
EXIT time to maximum, and when you FULL SET the system, the exit time
drops to 8 seconds as soon as the EXIT door has closed, thus avoiding the
preset exit time.
FULL SET KEYSWITCH
Allows the panel to be set, unset and reset through zone 8.
Note.
The keyswitch should be a spring loaded momentary type. To use
the keyswitch for setting, unsetting and so on, connect across zone 8 and
program that zone to be KEYSWITCH. To SET the panel, turn the key so the
contacts are open. Hold in this position for about a second for full set or
about 2 seconds for NIGHT SET. To UNSET the panel, turn and hold for
about ½ second. To Reset you must open and close the KEYSWITCH after
an alarm condition.
THE ACCEPT TONE
Heard when an action is accepted.
THE ERROR TONE
Heard when an action is not accepted.
SERIES AND PARALLEL
GLOSSARY OF
TERMS
LATCHING DETECTORS
These detectors, when triggered during a set period, latch on to aid the
process of alarm event origin checking. Use these detectors if many detec-
tors are to be used on a single zone but are to cover a large area of space.