11
By pressing the keys
1-8
on the keypad, you can select which zones to be
ISOLATED during Home Set. As you press a key, its relevant LED on the
display toggles ON or OFF. Any LEDs that are ON are ISOLATED during
Home Set, and any that are OFF remain ACTIVE.
ENGINEER ACCESS CODE 1-1
The default engineer access code is 7890. To change this code (while in
engineering mode), complete the following procedure.
1
Enter
1-1
.
LEDs 1, 2, 3 and 4 illuminate.
2
Enter the new 4-digit code.
After each key-press, one LED goes out
.
The speaker emits an accept tone if the new code is accepted.
If the speaker emits an error tone, then your new chosen code is invalid.
This could be due to a conflict with another code. At this time your old
access code is still valid. Repeat the procedure using a different code.
ENGINEER EVENT LOG REVIEW 5 (Choices of set & unset)
The panel stores the last 9 set and unset states and the last alarm event.
The log is arranged into SET and UNSET events. Log entries indicate the
first and subsequent alarms as well as isolated circuits. First to alarm is
shown by the LED being ON continuously. Subsequent alarms are shown
by the LED(s) flashing, and isolated circuits are shown by LED(s) pulsing
slowly. The buzzer sounds whilst reviewing the SET logs and is silent whilst
reviewing the UNSET logs.
To view the engineer logs, press the
5
key from the program mode. The log
starts viewing DAY 1 SET. View the remaining logs by pressing the relevant
key
2
for 2nd,
3
for 3rd, and so on up to
9
. Press the
0
key to get the last
alarm condition.
The
#
key alternates between SET and UNSET logs and can be used at any
time.
Pressing
*
exits the log displays and returns the main engineering mode.
ENGINEER TEST OPTIONS 6 (Range 0-5)
To conduct testing activities, first press the
6
key from within engineering
mode and then one of the following options.
Enter
0
Internal buzzer (entry exit sound etc.)
Enter
1
Internal Sounder (Alarm sounds from speaker/keypad)
Enter
2
External Sounder
Enter
3
External Strobe
Enter
4
L+ Terminal (even if programmed as ID-)
Enter
5
FULL LOAD (Everything enabled)
Press
*
to finish and return to main engineering mode.
ENGINEER
TEST OPTIONS
ENGINEER
LOG REVIEW
ENGINEER
ACCESS CODE