10
CIRCUIT PROGRAMMING 4 (Range 2-7)
You can program circuits 2-7 to suit your requirements. Circuit 1 is fixed as
a Final exit circuit. Circuit 8 has limited options.
ENTER
PROGRAM
ZONE
ENTER
PROGRAM
ZONE
4 - 2
2
4 - 6
6
4 - 3
3
4 - 7
7
4 - 4
4
4 - 8
8
4 - 5
5
Select the circuit you want to alter. You can then program that circuit by
entering one key from the following table.
N/S = Night Set
Option no.
Zones 2-7
Zone 8
1
Alarm
Alarm
2
Alarm with walk through
Fire
3
Alarm & Isolate in Night Set
PA
4
Alarm, Walk through & Isolate in N/S
Momentary
Keyswitch
5
Alarm, Walk through & N/S Entry
6
Fire
7
Entry Route
8
P.A
See the glossary for descriptions of zone types.
After you select the option, press
*
to confirm. The accept tone then
sounds.
To program zone 3 as an Entry Route enter
- 4 3 7 *
To program zone 8 as a Keyswitch enter
- 4 8 4 *
Momentary Keyswitch
Turn and hold for 0.5 seconds = FULL SET
Turn and hold for 2.0 seconds = PART SET
EXTENDED PROGRAMMING OPTIONS 7 (Range 1-8)
The control panel offers the following additional options.
Enter
7 - 1
Disables sounder and strobe in Night Set.
Enter
7 - 2
Chime Enable (See User Manual for zone allocation).
Enter
7 - 3
Full set door sense setting.
Enter
7 - 4
Convert L+ to ID- output.
Enter
7 - 5
Allow Manual Isolation of Zone 1 (Entry/Exit) In Night Set.
Enter
7 - 6
Remote Keypad PA Enable (Operated by * and #).
Enter
7 - 7
L+ signals first to alarm.
Enter
7 - 8
Inhibit strobe in Night and Home set and test (for speech
dialer connection).
Press
*
to confirm. The accept tone then sounds.
HOME SET ZONE SELECTION 8 (Range 1-8 N/A if Fire or PA)
The Home Set feature enables parts of the premises to be alarm protected
while other parts are occupied and in use. This feature is similar to Night
Set
except that an Exit/Entry route is not required as part of the Setting or
Unsetting procedure.
In programming mode press
8
to select Home Set zone selection mode.
HOME SET
ZONE
SELECTION
EXTENDED
PROGRAMMING
ZONE
SELECTIONS
CIRCUIT
PROGRAMMING