If no programming is required, close any lids that are open and press the
#
key. This exits engineering mode. Then refer to the Users Manual for
customer options.
If at any time you want to exit engineering mode, confirm any options you
have selected with the
*
(STAR) key. Then close ALL tamper circuits and
wait for approximately 60 seconds after which the panel automatically exits
engineering mode. Pressing the
#
key manually exits engineering.
If at any time you want to re-enter engineering mode, enter the engineering
code and then press the
#
key. This forces the panel into engineering mode.
Note:
If left unattended for approximately 60 seconds, it reverts to day
mode.
If you need to stay in engineering mode for longer unattended periods, once
in engineering mode, open a tamper circuit. The easiest way to do this is to
remove the lid of the panel or keypad.
PROGRAMMING
Once the panel is in engineering mode, the following options are available.
EXIT TIME 3-0 (Range 10-90 seconds)
Enter
3-0
. The factory default is 30 seconds. You can program a new time by
entering one key from the following list.
Enter
1
10 Seconds. LED 1 on.
Enter
2
15 Seconds. LED 2 on.
Enter
3
30 Seconds. LED 3 on. (Default)
Enter
4
45 Seconds. LED 4 on.
Enter
5
60 Seconds. LED 5 on.
Enter
6
90 Seconds. LED 6 on.
After choosing the desired option, press
*
to confirm. The accept tone then
sounds.
ENTRY TIME 3-1 (Range 10-90 seconds)
Enter
3-1
. The factory default is 30 seconds. To reprogram the entry time,
enter one key from the following list.
Enter
1
10 Seconds. LED 1 on.
Enter
2
15 Seconds. LED 2 on.
Enter
3
30 Seconds. LED 3 on. (Default)
Enter
4
45 Seconds. LED 4 on.
Enter
5
60 Seconds. LED 5 on.
Enter
6
90 Seconds. LED 6 on.
Press
*
to confirm the option. The accept tone then sounds.
NO
PROGRAMMING
NEEDED?
EXIT
ENGINEERING
MODE
RE-ENTER
ENGINEERING
MODE
STAY IN
ENGINEERING
MODE
TIMERS
EXIT TIME
ENTRY TIME