![Canary Systems MLRemote User Manual Download Page 32](http://html1.mh-extra.com/html/canary-systems/mlremote/mlremote_user-manual_3845417032.webp)
Section 3 ‒ MLWebHardware Configuration
32
MLRemote User's Guide
Push Program
If verification is successful, set the MLRemote to
Active
,
Save
the configuration, and click
Update
to send the
program to the MLRemote.
If this is the first time configuring the MLRemote, collection is not necessary and the program can be updated.
If making changes to an active station, it is advised that
Collect and Update
be selected. This collects any existing
data before over writing the program.
Note - Not collecting prior to pushing the new program deletes any uncollected data permanently.
Hint - Updating the program does not take effect immediately. The program is sent the next time the MLRemote checks in.
The next check in is determined by the Interval that was set in section 3.3 Program Configuration. The default interval when
the MLRemote is shipped is 1 minute.
Once the program has been pushed to the MLRemote, return to the MLRemote page to view the status. The
MLRemote is highlighted yellow while MLGateway is waiting to send the program. It then turns green once the
MLRemote has received the updated program.
Hint - See "MLRemote Status" in section 3.6 Station Status for a complete list of status colors.