7. Normal operation
.31.
.30.
In normal operation, LCD screen alternatively shows inverter power and operation status
(see Figure 7.1). The screen can be scrolled manually by pressing the UP/DOWN keys.
Pressing the ENTER key gives access to Main Menu.
5 sec
Start
Power 110000W
01-01-2020 00:00
Status: Generating
01-01-2020 00:00
Information
Settings
Advanced Info.
Advanced settings
UP/DOWN
UP/DOWN
UP/DOWN
UP/DOWN or
auto-scroll
(10 sec)
Pressing the
ENTER key
gives access to
the main menu.
Pressing the
ESC key
calls back the
previous menu.
Main Menu
Figure 7.1 Operation Overview
7.1 Main Menu
There are four submenus in the Main Menu (see Figure 7.1):
1. Information
2. Settings
3. Advanced Info.
4. Advanced Settings
The Canadian Solar three Phase Inverter main menu provides access to operational
data and information. The information is displayed by selecting "Information" from the
menu and then by scrolling up or down.
7.2 Information
7. Normal operation
Display
Duration
Description
Status: Waiting
Power: 0000W
Grid Frequency
F_Grid 00.00Hz
Total Energy
0000000 kwh
This Month: 0000kwh
Last Month: 0000kwh
Today: 0000.0kwh
Yesterday: 0000.0kwh
10 sec
10 sec
10 sec
10 sec
Status: Shows instant status of the Inverter.
Power: Shows instant output power value.
F_Grid: Shows the grid's frequency value.
Total generated energy value.
This Month: Total energy generated this month.
Last Month: Total energy generated last month.
Today: Total energy generated today.
Yesterday: Total energy generated yesterday.
Inverter
SN
00000000000000
10 sec
Display series number of the inverter.
10 sec
Rea_Power: 000000Var
App_Power: 000000VA
10 sec
Rea_Power: Shows the reactive power of the inverter.
App_Power: Shows the apparent power of the inverter.
Table 7.1 Information list
V_AB: Shows output voltage between phase A
and phase B.
I_AB: Shows output current between phase A
and phase B.
V_BC: Shows output voltage between phase B
and phase C.
I_BC: Shows output current between phase B
and phase C.
V_CA: Shows output voltage between phase C
and phase A.
I_CA: Shows output current between phase C
and phase A.
10 sec
10 sec
10 sec
V_AB: +801.0V
I_AB: +50.0A
V_BC: +801.0V
I_BC: +50.0A
V_CA: +801.0V
I_CA: +50.0A