11. Appendices
Parts
Torque
Cover screws
1.5-1.7 ft.lbs
Ground screws (Cover)
4.4-5.9 ft.lbs
AC terminals
7.4-14.6 ft.lbs
Ground screws (Internal)
7.4-8.9 ft.lbs
Figure 10.1 For all models of inverter
Comments:
A thermal sensor inside the inverter is calibrated to determine ambient temperature.
All inverters will begin a sloped derate at 45
°
C ending at 78% output power at 60
°
C.
Temperatures above 60
°
C and below -25
°
C will derate to 0% output power.
Ambient Temperature [
℃
]
Power(W)
185000
146160
580
850
1300
Voltage(V)
1500
11. Appendices
Power(W)
255000
146160
580
850
1300
Voltage(V)
1500
.64.
.65.
0
20
0
25
5
-
25
30
60
23
5
22
0
50
40
O
u
tp
u
t p
o
w
e
r [
k
W
]
P/V curve for CSI-185K-T600GL02-U
Figure 10.2 CSI-185K-T600GL02-U Inverter output power by input voltage
P/V curve for CSI-255K-T800GL02-U
Figure 10.3 CSI-255K-T800GL02-U Inverter output power by input voltage