Programming V/C via Potentiometer (Uadj/Iadj) – Stand Alone Operation 

The power supply is equipped with 2 potentiometers Uadj and Iadj for setting voltage and current.  
To enable the setting on the potentiometer, configure the interface via the DIP switch for 0-5V. Connect each 
Uadj and Iadj of CON3 to the inputs Ureg-IN and Ireg-IN. If one of the two potentiometers is not used, the other 
value can still be programmed via the interface. In such case, only the control signal 0-5V can be used. 

 

Fuse Mode  

The Fuse Mode can be used mode to prevent a major damage to a defective load. Fuse Mode can be activated 
via the associated switch S12 DIP switch. 
If the device is in the Fuse Mode (DIP switch S12=0), the device switches off when the constant current 
operation is taking longer than typ. 5s. The red OCP LED flashes with a period of 0,4s. The PSU is locked. The 
interlock can be canceled by the power supply is either switched off by the mains input, SB or SD contact for a 
moment. 

 

Continuous Mode 

If you select Continiuous Mode at DIP switch S12 (DIP switch S12=1), the device provides continuous power. It 
also applicable in the Constant Current Mode. Factory setup = Continuous Mode 

 

Over Load Behaviour 

The CPS-i changes from the standard operation mode into the high current mode when high and fast overload 
occurs. Thus, it provokes a restart after a 30ms break and delivers continuous current to the output. This 
special behaviour is a protection for the power supply and for the connected load. 

 

Compensation of Load Line Drop Voltage (Sense ++/--), standard operation mode 

The CPS-i power supply has a Sense Mode to compensate for the voltage drop over long load lines. The 
compensation amounts to a maximum of 2V per load line. Under certain circumstances, it can be expected to 
apply more complicated external interference suppression. If sense is not used, CON4 Sense +/+ and Sense -/- 
shall necessarily be connected by short bridges to the power outputs (factory setup). 
 
Sense operation: Remove the bridges between Sense +/+, Sense -/- and the power outputs. Connect the sense 
lines directly to the load. It is irrelevant which of the local connections Sense +/+ and Sense -/- are applied. Pay 
attention to the polarity of plus and minus of the load to prevent damage to the power supply. To avoid 
interference, twist the sense lines. To reduce inductive effects, we recommend that the load lines position is 
close to each other. To supply a pulsating load, the use of an electrolytic capacitor and a cermic capacitor has 
proved. The internal Over Voltage Protection (OVP) of the power supply controls the DC power directly to the 
DC output terminals. In case of an error the OVP acts automatically (see OVP values corresponding table).  
 
Operating in the sense mode requires that the maximum output voltage will not be exceeded. Maximum 2V per 
load lead can be compensated. The voltage drop in the load lines decreases the maximum output voltage 
rating. Example of a a 30V unit: if the total voltage drop in the load leads is 2V it is necessry to subtract this 
value from the maximum programmable output voltage 30V – 2V = 28V maximum available voltage at the load. 
 
The sense terminals are directly connected to the power outputs. 
 
                               

Local Sensing

                                                                                   

Remote Sensing

 

                               (factory setup)                                                                                    (twisted sense lines) 
 
 
 
 
 

WARNING! PROTECT TO MIX UP SENSE CONNECTIONS. THIS COULD CAUSE SERIOUS DAMAGE TO 
THE DEVICE. 

 
 

Summary of Contents for CPS-i3000

Page 1: ...ogramming Real time I V monitoring Reference voltage f autonomous programming CSB Current Share Bus Inhibit for safe interlocking Remote Shutdown Remote Shutdown Power Good Relay AC ok and DC ok Preci...

Page 2: ...gn specifications call for the highest standards of safety and interference suppression The device was developed in accordance with the requirements of EN61010 1 EN61010 2 201 EN62368 1 and the EMC st...

Page 3: ...no ticker operation Master Slave Mode Ureg OUT Ireg OUT The master slave mode can be defined in the parallel operation One device can be set as the master the other involved network units act as a sla...

Page 4: ...easuring point distance 10mm Hold Up Time 20ms 230Vac mains buffering at full load Inrush Current 14 6Aeff 20 7Apeak 230Vac active electronic inrush protection no simple NTC Startup Delay typ 1s Softs...

Page 5: ...nhibit Active Open Collector 9 OT Output Signal Over Temperature Open Collector 10 TA Output Signal Temperature Alarm Open Collector Early warning 11 OCP Output Signal Over Current Protection Open Col...

Page 6: ...el 49 721 46596 0 Fax 49 721 46596 77 www camtec gmbh com info camtec gmbh com Subject to alterations This product is not designed to be used in applications such as life support systems wherein a fai...

Page 7: ...C 250Vac 20A Neutrik PowerCon 3x2 5 mm Neutrik NAC3FCA Copy of the original instruction http www neutrik com de powercon powercon 20 a nac3fca Interface pluggable Push Pull Connectors from Weidmuelle...

Page 8: ...eries is an analog interface The output voltage is linearly proportional to the adjusted analog control signal If the control signal 0V and or 0A applies the power supply delivers 0V at the output The...

Page 9: ...urrent to the output This special behaviour is a protection for the power supply and for the connected load Compensation of Load Line Drop Voltage Sense standard operation mode The CPS i power supply...

Page 10: ...ibution in parallel operation of several identical CPS i units Define the power supply as the master which you want to address with your control A coding of the power modules as the master or the slav...

Page 11: ...ternatively a voltage of 10 to 30V typ 12V 1 5mA 24V 5 5mA can be applied If the standby repeals the power supply starts with a delay of 500ms Using the soft start the current and the voltage rises wi...

Page 12: ...y contacts changeover The contacts of CON1 Pin1 and CON1 Pin3 are closed relay coil is energized when the input voltage is higher than typ 175Vac or 210Vdc switch on The contacts of CON1 Pin5 and CON1...

Page 13: ...tween the TEMP signal and power output is a reinforced isolation of max 400Vdc and a basic isolation of max 600Vdc working voltage Temperature Control Signal PSOT of the PowerSink Fast Down Programmin...

Page 14: ...0A 24Vdc 125A 3000 3000W CPS i3000 060 60Vdc 50A 48Vdc 62 5A 3000 3000W CPS i3000 090 90Vdc 33 3A 72Vdc 41 5A 2997 2988W CPS i3000 150 150Vdc 20A 120Vdc 25A 3000 3000W CPS i3000 300 300Vdc 10A 240Vdc...

Page 15: ...her power supplies are not approved for series operation above 60Vdc If the units are remotely controlled via the analog interface it is compulsory to use a potential free control voltage Paralleling...

Page 16: ...Germany P 16 22 04 2016 01 5 Tel 49 721 46596 0 Fax 49 721 46596 77 www camtec gmbh com info camtec gmbh com Subject to alterations This product is not designed to be used in applications such as lif...

Page 17: ...l Safety Factory Test Field Test Owner 60Vdc 2800Vdc Type and factory test are the manufacturer While repating damage can happen to the power supply unit For the field test owner follow the below inst...

Page 18: ...sult in injury or death Mechanics Aluminium housing IP20 Cooling is achieved via front to rear fans To ensure adequate heat dissipation 50mm to the front and 150mm blockade free distance from the devi...

Page 19: ...lectronic current sink is used the output voltage remains constant at the set value The current sink provides fast dynamic response Fig 1 Fig 2 Fig 3 A Power Sink see Fig 1 enables fast down programmi...

Page 20: ...ww camtec gmbh com info camtec gmbh com Subject to alterations This product is not designed to be used in applications such as life support systems wherein a failure or malfunction could result in inj...

Page 21: ...to custom design power supplies Steplessly hard mount of the CPS i2000 3000 power supply modules in a 3D room In practice that means that one can mount the modules into every angle imaginable Our 3D H...

Page 22: ...3U 5 Modules mountable only in conjunction with front panel 3U orderable 2201005001CA 19 Rack Rail 2x Support Rails for rack mount mounting kit included 2201008001CA Cable Management Rail Cable suppor...

Reviews: