Open Collector Circuit Interface
Between all the open collector outputs and power output is a reinforced
isolation of max. 400Vdc and a basic isolation of max. 600Vdc working
voltage.
(Note: this applies to all signals from CON1 and CON2, regardless of whether
they are designed as open collector, or not)
Series Operation
Two or more units of the same model and output voltage can be operated up to a total voltage of 600Vdc in
series (not applicable to EN62368-1). Due to the dielectric strength of the internal components used, only the
models with an output voltage of 60Vdc and later are approved for series operation. Other power supplies are
not approved for series operation above 60Vdc.
If the units are remotely controlled via the analog interface it is compulsory to use a potential-free control
voltage!
Paralleling & N+1 Decoupling
To increase the overall power of the power supply, two or more devices of the same model with the same
output voltage may be operated in parallel. When using the Current Share Bus, the number of devices is limited
to 5 pcs. For applications without the Surrent Share Bus, more than 5 devices can be operated in parallel. For
power applications with a high dynamic range above 15kW, we recommend contacting our support team.
We recommend using a busbar for the DC power connector. Make sure that the cable lengths and cable cross-
sections of all power supplies to the busbar or to the star point are identical. Allow proper connection for low
contact resistance. Connect the sense lines to the star point or busbar. To avoid measurement errors, select
the line length from the star point or from the busbar to the load as short as possible and use the maximum
possible conductor cross-section.
The CPS-i models have no internal O-ring diode, to operate the devices N+1 redundant.