CPS-EC1500(R2) MANUAL
Camtec Power Supplies GmbH - Gewerbestrasse 30 - 76327 Pfinztal - Germany
P.3/13 (01/2017-02-1)
Phone +49(721)46596-0 - Fax +49(721)46596-77 -
www.camtec-gmbh.com
-
(Subject to alterations. This product is not designed to be used in applications such as life support systems wherein a failure or malfunction could result in injury or death)
Technical Data Table
AC Input Range
184 – 264Vac , 47 – 63Hz
DC Input Range
250Vdc – 375Vdc
AC Input Rated
230Vac<13,5A
DC Input Rated
250Vdc<7,5A 375Vdc<5,0A
DC Output Voltage Rated
24Vdc
36Vdc
48Vdc
60Vdc
72Vdc
110Vdc
150Vdc
220Vdc
400Vdc
DC Voltage Setting Range
24 –
30Vdc
36 –
45Vdc
48 –
58Vdc
60 –
75Vdc
72 –
90Vdc
110 –
137Vdc
132 –
180Vdc
220 –
264Vdc
330 –
400Vdc
DC Current Setting Range
31,3 –
62,5A
20,9 –
41,7A
15,6 –
31,2A
12,5 –
25,0A
10,4 –
20,8A
6,8 –
13,6A
5,0 –
10,0A
3,4 –
6,8A
2,3 –
4,6A
Over Voltage Protection
34Vdc
50Vdc
67Vdc
84Vdc
100Vdc
154Vdc
210Vdc
310Vdc
450Vdc
Over Current Protection
62,5A
41,7A
31,2A
25,0A
20,8A
13,6A
10,0A
6,8A
4,6A
Ripple Noise 230Vac 20MHz 40mV
80mV
120mV
150mV
200mV
300mV
400mV
400mV
400mV
Power Rated
1500W, 184-264Vac
Potentiometer C/V Setting
15 turns high precision, protective forced isolation to the inputs and the output 3000Vac
Operation Failure Relay
Yes, break contact, protective forced isolation to the inputs and the output 3000Vac
Sense Function
Compensation 2V per load line
Remote Shutdown
Yes, protective forced isolation to the inputs and the output 3000Vac
Inhibit Function (Interlock)
Yes, protective forced isolation to the inputs and the output 3000Vac
Derating
+60°C...+70°C 2.5%/°C
Accuracy
< ± 1.5% interface
Load Regulation
< ± 0.05% 0-100%
Start up from Shutdown
Typ. 420ms
Start up from Inhibit
Typ. 420ms
Response to Load Change
<1ms 10-100%, 100-10%
Base Load
None required (open circuit proof)
Efficiency 230Vac
92-94% at 90% load
Short Circuit Protection
Continuous
Open Circuit Proof
Continuous
Temperature Control
Yes, thermal shutdown with auto recovery (+70°C, metering distance 50mm)
Hold Up Time
>20ms 230Vac
Inrush Current ±5%
<14,7Aeff <20,7Apeak (230Vac) active inrush current limiter
MCB (Circuit Breaker)
16A type B
Soft Start
100ms typical
Cooling
Controlled and stepless fans from manufacturer EBM Papst (Germany)
Ambient Operating Temp.
- 25°C…+70°C
Ambient Storage Temp.
- 40°C…+85°C
Environment
Humidity 95% non-condensing @ 25°C, climate class. 3k3, pollution rate II
ROHS
2011/65/EU, (EU)2015/863
REACH
EG No. 1907/2006
EMI
EN55032 conducted class B, radiated class A, EN61000-6-3
EMS
EN61000-6-2
Safety
EN61010-1, EN61010-2-201, EN62368-1 (not 400Vdc model), EN60950-1, EN60204-1
Protection Class 1
PE connection required
Isolation Paths
> 8mm creepage distance & clearance paths
Input to Output Isolation
3000Vac
Input to Case Isolation
2500Vac
Output to Case Isolation
500Vdc , models
≥
48Vdc=2800Vdc
MTBF (IEC61709)
400000h (Meantime Between Failures: statistic time between failures after repairs)
MTTF (IEC61709)
144006h (Meantime To Failure: statistic time to ever fails)
Dimensions (HxWxD)
161x250x119.5mm
Weight
4,1kg / 9,0lbs
AC Terminals
Input Screw Terminal 3x AWG22 – AWG6 / 0,5 – 16mm² (L,N,PE)
DC Terminals
Output Screw Terminal 4x AWG22 – AWG6 / 0,5 – 16mm² (+ + / - - )