WARNING BEFORE REMOVING ANY GUARDS OR SAFETIES TURN “SELECTOR SWITCH” TO “OFF” 
POSITION AND DISCONNECT THE MAIN POWER AS THE SUPPLY FAN WILL CYCLE AUTOMATICALLY. 

 
IF HEATER FAILS TO START  
 

1.)  FOR BECKETT  BURNERS 7575 or 7590 PRESS AND HOLD THE RED BUTTON ON THE BECKETT 

CONTROLLER LOCATED ON THE CONTROL PANEL FOR 3 SECONDS TO RESET. FOR 7590 PRESS 
RED BUTTON TO RESET. 

2.)  FOR GAS OPERATION CHECK GAS PRESSURE SUPPLY.  SUPPLY AND MANIFOLD PRESSURE MUST 

FOLLOW THOSE ON RATING PLATE.  FOR OIL OPERATION CHECK FUEL LEVEL, FILTER, NOZZLE 
AND SUCTION TUBING. 

3.)  ENSURE PROPER POWER SUPPLY AND WIRE GAUGE IS BEING USED. 
4.)  IF HEATER FAILS TO IGNITE AFTER 3 ATTEMPTS, CALL YOUR SUPPLIER FOR SERVICE. 

 

NOTE: 

IF UNIT HAS BEEN RESET A NUMBER OF TIMES WITHOUT IGNITION --

  DO NOT ATTEMPT TO START 

THE HEATER: CONTACT A QUALIFIED SERVICE TECHNICIAN.  

NOTE: IN OIL OPERATION 

IF UNIT HAS BEEN RESET A NUMBER OF TIMES WITHOUT IGNITION THERE WILL 

BE AN ACCUMULATION OF OIL IN THE COMBUSTION CHAMBER

!  DO NOT ATTEMPT TO START THE 

HEATER: CONTACT A QUALIFIED SERVICE TECHNICIAN. 

 

CAUTION 

1.)  DO NOT SHUT OFF BY DISCONNECTING SUPPLY CORD.  THE HEAT EXCHANGER SHOULD BE 

PROPERLY COOLED BEFORE POWER SHUTDOWN. 

2.)  ALWAYS MAINTAIN ADEQUATE FUEL SUPPLY. 
3.)  IF GAS BURNER IS INSTALLED HEATER IS FOR USE WITH PROPANE OR NATURAL GAS ONLY.  

SEE APPROVAL LABEL. 

4.)  DO NOT PLUG ANYTHING OTHER THAN THE THERMOSTAT INTO THE “REMOTE STAT” PLUG. 
5.)  FOLLOW ELECTRICAL REQUIREMENTS SHOWN ON RATING PLATE AND/OR ELECTRICAL 

REQUIREMENTS SECTION OF THIS MANUAL. 

6.)  IN OIL OPERATION DO NOT START THE HEATER WHEN EXCESS OIL HAS ACCUMULATED IN 

CHAMBER. 

7.)  IN OIL OPERATION DO NOT FILL TANK WHILE UNIT IS OPERATING. 
8.)  IN NO CASE SHOULD POWER CABLES BE SMALLER THAN WHAT IS STIPULATED ON 

NAMEPLATE AND INSTRUCTION MANUAL. 

9.)  IN OIL OPERATION DO NOT USE GASOLINE, CRANKCASE OIL OR HEAVIER THAN NO. 2 FURNACE 

OIL. 

10.)   DO NOT START THE HEATER WHEN THE CHAMBER IS HOT 
11.) DO NOT FILL THE TANK WHILE THE UNIT IS OPERATING 
12.) DO NOT TAMPER WITH THE UNIT.  HAVE A COMPETENT SERVICE-TECHNICIAN MAKE ANY 

ADJUSTMENTS 

13.) MAX OUTLET TEMPERATURE (U.S./CA) 280F 
14.) AT INSTALLATION ELEVATIONS ABOVE 2000 FT (610m), THE APPLIANCE SHALL BE DERATED 4 

PERCENT FOR EACH 1000 FT (305m) OF ELEVATION ABOVE SEE LEVEL 

15.) SHOULD OVERHEATING OCCUR, OR THE GAS SUPPLY CONTROL SYSTEM FAIL TO SHUT OFF 

THE FLOW OF GAS, SHUT OFF THE MANUAL GAS VALVE TO THE UTILITY HEATER BEFORE 
SHUTTING OFF THE ELECTRICAL SUPPLY. 

16.) DO NOT USE THIS UTILITY HEATER IF ANY PART HAS BEEN UNDER WATER. IMMEDIATELY CALL 

A QUALIFIED SERVICE TECHNICIAN TO INSPECT THE HEATER AND REPLACE ANY GAS 
CONTROL WHICH HAS BEEN UNDER WATER. 

 

ELECTRICAL REQUIREMENTS: 15 AMPS (1PH)  

 

 
 

Summary of Contents for ECOBlaze 200D Turbo

Page 1: ...P a g e 1 OIL NG LP FIRED SPACE HEATER BLAZE 200 D G TURBO WWW CAMPOEQUIPMENT COM REPORT 0367MH007S Installation Instructions Manual Maintenance Parts List CAUTION DO NOT TAMPER WITH HEATER OR ITS CON...

Page 2: ...CAMPO EQUIPMENT CO LTD ECOBLAZE 6 Carson Court Brampton ON CANADA L6T 4P8 Tel 905 793 2525 Fax 905 793 8768 www campoequipment com P a g e 2...

Page 3: ...TALL THE HEATER MUST HAVE THE TRAINING AND EXPERIENCE NECESSARY TO DO SO READ THIS MANUAL CAREFULLY FAILURE TO PROPERLY INSTALL AND SETUP THE HEATER COULD RESULT IN PROPERTY DAMAGE PERSONAL INJURY OR...

Page 4: ...UALIFIED PLUMBER AND GAS FITTER OF THE STATE OF MASSACHUSETTS THE INSTALLATION OF THIS HEATER FOR USE WITH A PROPANE TANK OR CYLINDER SHALL CONFORM WITH LOCAL CODES OR IN THE ABSENCE OF LOCAL CODES WI...

Page 5: ...OUT PUSH THE RED RESET BUTTON ONLY ONCE IF THE BURNER DOES NOT RE LIGHT DO NOT PUSH THE BUTTON A SECOND TIME OR EXCESS OIL WILL ACCUMULATE IN THE COMBUSTION CHAMBER CALL A QUALIFIED SERVICE PERSON INS...

Page 6: ...1 X 12 1 X 12 Gas Conversion Easy switch over Blue handle Ball Valve on Gas manifold Closed position Propane Open position Natural Gas N A Manifold pressure W C 3 5 NG or 3 5 LP Pressure to be set be...

Page 7: ...CONNECTION BETWEEN THE PROPANE SUPPLY CYLINDER S AND THE HEATER MUST BE DISCONNECTED AND THE CYLINDERS REMOVED FROM THE HEATER AND STORED IN ACCORDANCE WITH STANDARDS FOR THE STORAGE AND HANDLING OF...

Page 8: ...HE FUEL THE HEATER IS BURNING DO NOT OPERATE THE HEATER WITHOUT CONSULTING THE RATING PLATE HEATER CONVERSION MUST BE DONE BY A QUALIFIED TECHNICIAN AND RATING PLATE MUST REFLECT ANY CHANGE THIS UNIT...

Page 9: ...PPLIED WITH THE APPLIANCE MUST BE REPLACED IT MUST BE REPLACED WITH TYPE TEW 14GA WIRE OR ITS EQUIVALENT ELECTRICAL SYSTEM BLAZE 200 D G Volts Hertz Phase 120 60 1 Full Load Amps 9 Max fuse size in AM...

Page 10: ...CAMPO EQUIPMENT CO LTD ECOBLAZE 6 Carson Court Brampton ON CANADA L6T 4P8 Tel 905 793 2525 Fax 905 793 8768 www campoequipment com P a g e 10 Blaze 200D Turbo Schematic Beckett AFG Oil Burner...

Page 11: ...CAMPO EQUIPMENT CO LTD ECOBLAZE 6 Carson Court Brampton ON CANADA L6T 4P8 Tel 905 793 2525 Fax 905 793 8768 www campoequipment com P a g e 11 Blaze 200G Turbo Schematic Beckett CG4 Burner...

Page 12: ...switch heats up to factory set point 110F and circulating air blower starts 4 When the selector switch is placed to the off position the burner shuts down 5 The circulating blower continues to operate...

Page 13: ...BEFORE POWER SHUTDOWN 2 ALWAYS MAINTAIN ADEQUATE FUEL SUPPLY 3 IF GAS BURNER IS INSTALLED HEATER IS FOR USE WITH PROPANE OR NATURAL GAS ONLY SEE APPROVAL LABEL 4 DO NOT PLUG ANYTHING OTHER THAN THE T...

Page 14: ...feet BURNER END 3 feet DISCHARGE END 10 feet VENT CONNECTOR 3 feet COMBUSTIBLE FLOOR 6 feet FLUE PIPE CONNECTIONS VENT TO OUTDOORS FOR INSTALLATION ON NON COMBUSTIBLE FLOORS ONLY When the heater is c...

Page 15: ...ICIENT DISCHARGE AIR WILL CAUSE THE HEATER TO OVERHEAT BLAZE 200 D G TURBO MAINTENANCE INSTRUCTIONS WARNING EVERY CONSTRUCTION HEATER SHOULD BE INSPECTED BEFORE EACH USE AND AT LEAST ANNUALLY BY A QUA...

Page 16: ...frayed wires exposed FAN Check for dust or dirt build up on blades Run heater to check for fan vibration Replace fan blade if vibration is noticeable The flow of combustion and ventilation air must n...

Page 17: ...AFTER INSPECTION A COMPLETE COMBUSTION TEST MUST BE PEFORMED AFTER EACH ANNUAL SERVICE OF THE UNIT TO MAINTAIN OPTIMUM PERFORMANCE AND RELIABILITY WARNING TURN OFF THE FUEL SUPPLIES AND POWER BEFORE P...

Page 18: ...altitude and type of fuel used BECKETT CG4 THE BECKETT CG4 BURNER IS DESIGNED TO BE USED SOLELY WITH THE BECKETT 7590 GAS BURNER PRIMARY CONTROL AND THE 7474 GAS IGNITER 1 Loosen shutter and band and...

Page 19: ...e unit begins to produce smoke Increase air until no smoke is produced Check for excessive heat build up in the heat exchanger Insufficient air will cause flame impingement and reduced heat exchanger...

Page 20: ...mmended pump pressure 175 psi is recommended 3 Check nameplate for recommended air setting A 4 2 air setting is recommended 4 Install a pressure gauge in pump gauge port and start the burner Operate f...

Page 21: ...CAMPO EQUIPMENT CO LTD ECOBLAZE 6 Carson Court Brampton ON CANADA L6T 4P8 Tel 905 793 2525 Fax 905 793 8768 www campoequipment com P a g e 21 BECKETT AFG PARTS BREAKDOWN...

Page 22: ...CAMPO EQUIPMENT CO LTD ECOBLAZE 6 Carson Court Brampton ON CANADA L6T 4P8 Tel 905 793 2525 Fax 905 793 8768 www campoequipment com P a g e 22...

Page 23: ...EQUIPMENT CO LTD ECOBLAZE 6 Carson Court Brampton ON CANADA L6T 4P8 Tel 905 793 2525 Fax 905 793 8768 www campoequipment com P a g e 23 For replacement parts please contact Campo Equipment 1 866 323...

Reviews: