background image

 

CAMPO EQUIPMENT CO. LTD. (ECOBLAZE) 

6 Carson Court, Brampton, ON, CANADA, L6T 4P8 

Tel: (905) 793-2525 | Fax: (905) 793-8768 | 

www.campoequipment.com

 

P a g e

 | 

5

 

 

DO NOT TAMPER WITH THE HEATER AND CONTROLS!  THE HEATER MUST BE SERVICED BY 
QUALIFIED SERVICE PERSONNEL. 
 

WARNING

THOSE WHO INSTALL THE HEATER MUST HAVE THE TRAINING AND EXPERIENCE 

NECESSARY TO DO SO.  READ THIS MANUAL CAREFULLY.  FAILURE TO PROPERLY INSTALL 
AND SETUP THE HEATER COULD RESULT IN PROPERTY DAMAGE, PERSONAL INJURY, OR LOSS 
OF LIFE.  THE QUALIFIED SERVICE PERSONNEL PERFORMING THIS WORK ASSUMES A SERIOUS 
RESPONSIBILITY FOR THE CORRECT INSTALLATION, SETUP, AND START-UP OF THE HEATER. 

 
THESE INSTRUCTIONS HAVE BEEN THOROUGHLY WRITTEN, BUT THEY CANNOT COVER EVERY 
PECULIAR INSTALLATION AND CONTINGENCY.  THEREFORE IF THERE IS ANY DOUBT AS TO 
INTERPRETATION OF ANY REQUIREMENTS, CONTACT YOUR LOCAL AUTHORITY HAVING 
JURISDICTION, YOUR LOCAL DISTRIBUTOR, OR THE FACTORY. 
 
IMPORTANT: IF YOU OBSERVE THE PRIMARY CONTROL IS LOCKED OUT, PUSH THE RED RESET 
BUTTON ONLY ONCE.  IF THE BURNER DOES NOT RE-LIGHT, DO NOT PUSH THE BUTTON A 
SECOND TIME OR EXCESS OIL WILL ACCUMULATE IN THE COMBUSTION CHAMBER—CALL A 
QUALIFIED SERVICE PERSON. 
 
INSTALLATION REGULATIONS:   

1.)  INSTALLATION SHOULD BE IN ACCORDANCE WITH ALL LOCAL AND NATIONAL 

REGULATIONS. 

2.)  IN CANADA USE THE CSA B139-1962 INSTALLATION CODE FOR OIL BURNING EQUIPMENT, 

FOR RECOMMENDED INSTALLATION PRACTICE. 

 
WIRING:  ALL INTERNAL WIRING OF THE HEATER IS COMPLETED BY THE MANUFACTURER.  ALL 
EXTERNAL WIRING MUST CONFORM TO EXISTING ELECTRICAL CODES AS LAID DOWN BY THE 
AUTHORITIES HAVING JURISDICTION.  IN CANADA, REFER TO CSA C22.1 CANADIAN ELECTRICAL 
CODE AND IN THE UNITED STATES AS OUTLINED IN THE BOCA CODE, OR THE NFPA 70 NATIONAL 
ELECTRICAL CODE. 
 

WARNING: LACK OF COMBUSTION AIR CAN CAUSE A DIRTY FIRE, ODOURS IN ENCLOSED 
SPACES, AND BACKDRAFTING, POTENTIALLY RESULTING IN NAUSEA OR ASPHYXIATION OF 
THE OCCUPANTS. 

 

 
 

BLAZE 200 D/G 
SPECIFICATIONS

 

BLAZE 200G-
BECKETT (NG/LP) 

 

BLAZE 200D-  
BECKETT (OIL) 

Burner Make & Model

 

Beckett CG4 

 

Beckett AFG 

Voltage

 

120V 
 

 

120V 

Input (BTU/h) 

 

175,000 

 

NO.1 (172,599) @ 175 PSI  
NO.2 (175,000) @ 175 PSI  
 

CFM/AMPS   

 

2,750/9 

 

2,750/9 

MOTOR HP

 

 

.67 

 

 

.67 

Summary of Contents for ECOBlaze 200D Turbo

Page 1: ...P a g e 1 OIL NG LP FIRED SPACE HEATER BLAZE 200 D G TURBO WWW CAMPOEQUIPMENT COM REPORT 0367MH007S Installation Instructions Manual Maintenance Parts List CAUTION DO NOT TAMPER WITH HEATER OR ITS CON...

Page 2: ...CAMPO EQUIPMENT CO LTD ECOBLAZE 6 Carson Court Brampton ON CANADA L6T 4P8 Tel 905 793 2525 Fax 905 793 8768 www campoequipment com P a g e 2...

Page 3: ...TALL THE HEATER MUST HAVE THE TRAINING AND EXPERIENCE NECESSARY TO DO SO READ THIS MANUAL CAREFULLY FAILURE TO PROPERLY INSTALL AND SETUP THE HEATER COULD RESULT IN PROPERTY DAMAGE PERSONAL INJURY OR...

Page 4: ...UALIFIED PLUMBER AND GAS FITTER OF THE STATE OF MASSACHUSETTS THE INSTALLATION OF THIS HEATER FOR USE WITH A PROPANE TANK OR CYLINDER SHALL CONFORM WITH LOCAL CODES OR IN THE ABSENCE OF LOCAL CODES WI...

Page 5: ...OUT PUSH THE RED RESET BUTTON ONLY ONCE IF THE BURNER DOES NOT RE LIGHT DO NOT PUSH THE BUTTON A SECOND TIME OR EXCESS OIL WILL ACCUMULATE IN THE COMBUSTION CHAMBER CALL A QUALIFIED SERVICE PERSON INS...

Page 6: ...1 X 12 1 X 12 Gas Conversion Easy switch over Blue handle Ball Valve on Gas manifold Closed position Propane Open position Natural Gas N A Manifold pressure W C 3 5 NG or 3 5 LP Pressure to be set be...

Page 7: ...CONNECTION BETWEEN THE PROPANE SUPPLY CYLINDER S AND THE HEATER MUST BE DISCONNECTED AND THE CYLINDERS REMOVED FROM THE HEATER AND STORED IN ACCORDANCE WITH STANDARDS FOR THE STORAGE AND HANDLING OF...

Page 8: ...HE FUEL THE HEATER IS BURNING DO NOT OPERATE THE HEATER WITHOUT CONSULTING THE RATING PLATE HEATER CONVERSION MUST BE DONE BY A QUALIFIED TECHNICIAN AND RATING PLATE MUST REFLECT ANY CHANGE THIS UNIT...

Page 9: ...PPLIED WITH THE APPLIANCE MUST BE REPLACED IT MUST BE REPLACED WITH TYPE TEW 14GA WIRE OR ITS EQUIVALENT ELECTRICAL SYSTEM BLAZE 200 D G Volts Hertz Phase 120 60 1 Full Load Amps 9 Max fuse size in AM...

Page 10: ...CAMPO EQUIPMENT CO LTD ECOBLAZE 6 Carson Court Brampton ON CANADA L6T 4P8 Tel 905 793 2525 Fax 905 793 8768 www campoequipment com P a g e 10 Blaze 200D Turbo Schematic Beckett AFG Oil Burner...

Page 11: ...CAMPO EQUIPMENT CO LTD ECOBLAZE 6 Carson Court Brampton ON CANADA L6T 4P8 Tel 905 793 2525 Fax 905 793 8768 www campoequipment com P a g e 11 Blaze 200G Turbo Schematic Beckett CG4 Burner...

Page 12: ...switch heats up to factory set point 110F and circulating air blower starts 4 When the selector switch is placed to the off position the burner shuts down 5 The circulating blower continues to operate...

Page 13: ...BEFORE POWER SHUTDOWN 2 ALWAYS MAINTAIN ADEQUATE FUEL SUPPLY 3 IF GAS BURNER IS INSTALLED HEATER IS FOR USE WITH PROPANE OR NATURAL GAS ONLY SEE APPROVAL LABEL 4 DO NOT PLUG ANYTHING OTHER THAN THE T...

Page 14: ...feet BURNER END 3 feet DISCHARGE END 10 feet VENT CONNECTOR 3 feet COMBUSTIBLE FLOOR 6 feet FLUE PIPE CONNECTIONS VENT TO OUTDOORS FOR INSTALLATION ON NON COMBUSTIBLE FLOORS ONLY When the heater is c...

Page 15: ...ICIENT DISCHARGE AIR WILL CAUSE THE HEATER TO OVERHEAT BLAZE 200 D G TURBO MAINTENANCE INSTRUCTIONS WARNING EVERY CONSTRUCTION HEATER SHOULD BE INSPECTED BEFORE EACH USE AND AT LEAST ANNUALLY BY A QUA...

Page 16: ...frayed wires exposed FAN Check for dust or dirt build up on blades Run heater to check for fan vibration Replace fan blade if vibration is noticeable The flow of combustion and ventilation air must n...

Page 17: ...AFTER INSPECTION A COMPLETE COMBUSTION TEST MUST BE PEFORMED AFTER EACH ANNUAL SERVICE OF THE UNIT TO MAINTAIN OPTIMUM PERFORMANCE AND RELIABILITY WARNING TURN OFF THE FUEL SUPPLIES AND POWER BEFORE P...

Page 18: ...altitude and type of fuel used BECKETT CG4 THE BECKETT CG4 BURNER IS DESIGNED TO BE USED SOLELY WITH THE BECKETT 7590 GAS BURNER PRIMARY CONTROL AND THE 7474 GAS IGNITER 1 Loosen shutter and band and...

Page 19: ...e unit begins to produce smoke Increase air until no smoke is produced Check for excessive heat build up in the heat exchanger Insufficient air will cause flame impingement and reduced heat exchanger...

Page 20: ...mmended pump pressure 175 psi is recommended 3 Check nameplate for recommended air setting A 4 2 air setting is recommended 4 Install a pressure gauge in pump gauge port and start the burner Operate f...

Page 21: ...CAMPO EQUIPMENT CO LTD ECOBLAZE 6 Carson Court Brampton ON CANADA L6T 4P8 Tel 905 793 2525 Fax 905 793 8768 www campoequipment com P a g e 21 BECKETT AFG PARTS BREAKDOWN...

Page 22: ...CAMPO EQUIPMENT CO LTD ECOBLAZE 6 Carson Court Brampton ON CANADA L6T 4P8 Tel 905 793 2525 Fax 905 793 8768 www campoequipment com P a g e 22...

Page 23: ...EQUIPMENT CO LTD ECOBLAZE 6 Carson Court Brampton ON CANADA L6T 4P8 Tel 905 793 2525 Fax 905 793 8768 www campoequipment com P a g e 23 For replacement parts please contact Campo Equipment 1 866 323...

Reviews: