8
Beckett Burner pump. For a 1 line system remove bypass plug located on inlet port of Beckett
Pump and just connect fuel line to inlet side of fuel filter.
FUEL (BLAZE 200 G TURBO)
THIS HEATER WILL OPERATE ON PROPANE
OR
NATURAL GAS—
NOT BOTH
. THE
MANIFOLD PRESSURES ARE LISTED ON THE APPROVAL LABEL. TO DETERMINE WHICH
FUEL TO USE SEE RATING PLATE.
DO NOT
ATTEMPT TO USE THE HEATER WITHOUT
CONSULTING THE RATING PLATE.
NOTE: THE PROPER POSITION ON THE EASY SWITCH OVER BLUE HANDLE BALL VALVE
MUST BE USED AND RATING PLATE MUST REFLECT THE FUEL THE HEATER IS BURNING.
DO NOT
OPERATE THE HEATER WITHOUT CONSULTING THE RATING PLATE.
HEATER CONVERSION MUST BE DONE BY A QUALIFIED TECHNICIAN AND RATING PLATE
MUST REFLECT ANY CHANGE.
THIS UNIT HEATER IS EQUIPPED FOR NATURAL GAS OR LP GAS. THIS UNIT HEATER IS
EQUIPPED WITH ORIFICES SIZED FOR OPERATION WITH NATURAL OR LP GAS VIA THE
EASY SWITCH OVER BLUE HANDLE BALL VALVE. FOR CONVERSION TO LP (OR
NATURAL) GAS SEE INSTRUCTION PLATE ON THE APPLIANCE.
Easy
switch
over
Blue
handle
Ball
Valve
on
Gas
manifold.
Closed
position:
Propane
Open
position:
Natural
Gas
HOSES
ALL HOSES USED TO CONNECT THIS HEATER TO FUEL SUPPLY MUST BE TYPE 1
APPROVED PROPANE/NATURAL GAS HOSE ASSEMBLIES.
ELECTRICAL
WARNING: ELECTRICAL GROUNDING INSTRUCTIONS
THIS APPLIANCE IS ABLE IS TO RECEIVE 1 PHASE POWER.
120V SUPPLY MUST BE AVAILABLE.
INSTALLATION
12/3 AWG UPTO 50FT
10/3 AWG BEYOND 50FT