Hardwiring the ele ctrical connections:
●
Wiring should be carried out by a qualified electrician in accordance with local
codes.
●
The water heater requires 120 VAC/60Hz and should be properly grounded.
●
DO NOT connect grounding wire to water pipes, gas pipes, telephone cables,
lightning conductor circuits and to grounding circuit of other equipment that
carry a ground-fault interrupter.
●
An ON/OFF switch must be provided and installed for the incoming 120VAC
power.
●
Wire the water heater exactly as shown below. A wiring diagram is also found
inside of the cover panel.
●
A green screw is provided in the junction box for grounding connection.
●
Connect the live wire to black leg wire and the neutral wire to the white neutral
wire.
CAUTION: Label all wires prior to disconnection when servicing
controls. Wiring errors can cause improper and dangerous operation. Verify
correct operation after servicing.
Electric Wiring Diagram
WIFI
A
Ground Wire
Thermostat
Panel Display(Indoor)
Fan
Remote Control(Outdoor)
Ignition Pin
Feedback Wire
Water Flow Sensor
Water Ratio Valve
Temp. Sensor of Water Inlet
Temp. Sensor of Water Outlet
Ground Wire
Gas Proportion Valve(A)
Gas Main Valve (B)
Section
Valve C
Section
Valve D
Anti-freezer
for Certain
Models
Power Cord
Ground Wire
B
D
C
E*
Heat Exchanger Protection Device
Thermostat
W
G
G
W
W
G
W
W
R- Y -W -BL
W
W
BK
BK
BL
BL
BK
Y
R
BL
Y-O-Gr-Bl-Br-R-W-Bk
Bk-----Black
Bl------Blue
Br-------Brown
Pl------Purple
Gn------Green
Gy-------Gray
Y--------- Yellow
W--------White
R--------Red
O-------Orange
R
Br
Y
Bk
Bk
Bl
Bk
Pl
Pl
Gn
1
26
Visit Us: Camplux.com
3330-A Marathon Ct Charleston, SC 29418