In regards to the HOT WATER OUTLET:
●
Connections between the water heater and point(s) of use should be as short
and direct as possible.
●
DO NOT use lead or non-approved plastic pipe.
●
To conserve energy and minimize heat loss, insulation of hot water piping is
recommended.
NOTICE:
The flow rate of hot water may vary when more than two faucets
(appliances, fixtures, etc.) are being used simultaneously.
NOTICE:
The pipes MUST be completely drainable. If the hot water faucets are
located at a point higher than the water heater, place a drain valve at the lowest
point (see diagram to the left).
Gas supply
WARNING: Do not attempt to convert this water
heater for use with a different type of gas other than the
type shown on the rating plate. Such conversion could
result in hazardous operating conditions. Please have
a professional connect the gas pipe.
The supplied Manual Gas Appliance Shutoff Valve must
be installed at the gas connection of the water heater at
the time of installation (see diagram to the left).
The branch gas supply line to the water heater should be
clean black steel pipe or other approved gas piping
material. A ground joint union or ANSI design certified
semi-rigid or flexible gas appliance connector should be
installed in the gas line close to the water heater.
The National Fuel Gas Code (NFGC) mandates a manual gas shut-off valve: See
(NFGC) for complete instructions.
Hot Water Tap
Drain Valve