NOTICE:
The pipes MUST be completely drainable. If the hot water faucets are
located at a point higher than the water heater, place a drain valve at the lowest
point (see illustration to the bottom left).
Gas supply
WARNING: Do not attempt to convert this water heater for use with a
different type of gas other than the type shown on the rating plate. Such
conversion could result in hazardous operating conditions. Please have a
professional connect the gas pipe.
A Manual Gas Appliance Shutoff Valve must be installed at
the gas connection of the water heater at the time of
installation (see diagram to the left). The branch gas supply
line to the water heater should be clean black steel pipe or
other approved gas piping material.
A ground joint union or ANSI design certified semi-rigid or
flexible gas appliance connector should be installed in the
gas line close to the water heater. The National Fuel Gas
Code (NFGC) mandates a manual gas shut-off valve: See
(NFGC) for complete instructions.
If flexible connectors are used, the maximum length shall
not exceed 36″.
If lever type gas shut offs are used, they shall be T-Handle
type.
Compound used on the threaded joints of the gas piping must be of the type
resistant to the action of LP gas. Use compound sparingly on male threads only.
A sediment trap should be installed at the bottom of the gas line.